AMX Precis SD Power Receptacle & Specifications, System Serial Number, Input & Output Connectors

Page 15

Overview & General Specifications

Power Receptacle & Specifications

The universal power receptacle is in the lower left hand corner on the rear of the enclosure (FIG. 4). Maximum power specifications are on the power receptacle. The power receptacle will accept all major international standard power sources. (Standard US power cords are provided for installations within the US.)

The fuse is internal and is not field serviceable. If you believe the fuse needs to be replaced, contact technical support (see page 32).

Serial number labels

Input connectors

Output connectors

Power receptacle & specifications

 

 

 

FIG. 4 Enclosure hardware

System Serial Number

The system’s serial number is normally located in two places on an enclosure. When viewed from the rear, one serial number label is on the CPU (FIG. 4). The second serial number label is on the left side of the enclosure at the bottom edge (near the power receptacle). The label on the side will also have the enclosure number (referred to as the chassis number). Precis SD systems are contained in a single enclosure, labeled “Chassis 1 of 1.” Before installation, we recommend recording the system’s serial number in an easily accessible location.

Input & Output Connectors

Input and output connectors are the attachment points for source and destination devices that connect to the system. Viewed from the rear of the enclosure, the inputs (sources) are on the left side of the enclosure, and the outputs (destinations) are on the right side of the enclosure. The BNC connectors are color coded; the white connectors are inputs and the black connectors are outputs. Inputs and outputs are numbered separately; the numbers are above the connector on the left.

For directions on cabling/wiring the input and output connectors in your system, see “Attaching Inputs & Outputs” on page 24.

10

Precis SD Instruction Manual

Image 15
Contents Precis SD AMX Limited Warranty and Disclaimer Software License and Warranty Agreement Contents Appendix a Managing Configuration Files ESD Warning Important Safety Information & Instructions Information et directives de sécurité importantes Copyright Notice Liability NoticeUsfcc Notice Trademark Notices Lithium Batteries NoticePage Product Notes Overview & General SpecificationsPrecis SD Features Applicability NoticeFront View Precis SD Control FeaturesRear View Rear View ComponentsCPU/Control Hardware Power Receptacle & Specifications Input & Output ConnectorsSystem Serial Number General Specifications Precis SD General SpecificationsAMX Control Software Configuration Information & Control OptionsFront Control Panel AMX Control DevicesBCS Serial Control Protocol Third-Party Controllers Overview & General Specifications Installation & Setup General Hazard PrecautionsSite Recommendations Unpacking Tips UnpackingCircuit Overloading Reliable Earthing GroundingInstallation Recommendations Rack Installation & System SetupRequired items for rack installation Optional items for rack installationTo install and set up a Precis SD system in a rack Installation ProcedureAdditional Installation Options Attaching External Controllers PC Requirements for BCS RS-232 Pin DiagramAttaching Serial Controllers PC Requirements for APControlChange the enclosure’s settings instead, use XNConnect see Attaching External XNNet Controllers Communication Cable RequirementsTo establish a Remote port connection with an XNNet device Attaching Inputs & Outputs Signal Types & ConnectorsTo connect video inputs and outputs Cabling Video ConnectorsTo attach stereo audio input and output wires Wiring Audio ConnectorsWiring Sources & Destinations Attaching WiresPower-Up Sequence To apply power Applying Power & StartupHyperTerminal Serial Control Device StartupAPControl APWebExecuting a Test Switch Executing a Test SwitchAPControl 3.0 or APWeb To execute a test switch using the control panelControl Panel AMX Control DeviceTroubleshooting BCS CommandsTo disconnect the factory default switch using BCS commands To execute a test switch using BCS commandsAMX Contact Information Technical SupportSignal Specifications Ultra-Wideband 500 MHz SpecificationsSync Specifications Standard Audio Signal Specifications Standard Audio SpecificationsOverview Precis SD Control Panel OperationVirtual Matrices Levels Audio Adjust Keys optionalControl Keys Modes of OperationTo execute a switch selecting input source first Executing & Disconnecting SwitchesSwitching Level Executing a SwitchTo execute a switch selecting output destination first Disconnecting OutputsTo disconnect an output To verify the status of a signal Verifying Signal StatusExecuting Macros Local Presets Adjusting Audio Adjusting Output VolumeTo adjust output volume Purpose & Uses of Input Gain Adjusting Digital Input GainTo adjust digital input gain to equalize input levels To adjust digital input gainLocking & Unlocking the Control Panel To lock the control panelTo unlock the control panel Precis SD Control Panel Operation Applicability Notice Appendix a Managing Configuration FilesTo launch XNConnect Installing & Launching XNConnectTo install XNConnect from the AMX AutoPatch CD System RequirementsTo discover a system Discovering a SystemTo open an .xcl file Opening an .xcl Configuration FileNavigating the Interface Hardware ViewVirtual Matrix View Modifying an .xcl Configuration File Modifying Source & Destination Channel NamesTo customize the channel names To set the control panel password Setting the Control Panel PasswordTo create a new local preset Creating Local Presets MacrosAppendix a Managing Configuration Files Device Discovery Support Loading an .xcl Configuration FileSystem Component Information Appendix B Programmer’s Interface for System DiagnosticsExample Using BCS to Access System Diagnostic InformationDisplay for v1i1 verbosity 1, component Splash Screen ExamplesDisplay for v3i5 verbosity 3, component It’s Your World Take Control