Accton Technology 4508, CheetahSwitch Workgroup manual Panel Display, Console Configuration

Page 55

Management Guide

Panel Display

The Web Agent displays an image of the switch’s ports, showing port link and activity. Clicking on the image of a port displays statistics and configuration information for the port. Clicking on the image of the serial port (labelled “Mgmt”) displays the Console Configuration screen.

Console Configuration

Click on the serial port icon in the switch image to display and configure the out-of- band serial port connection, as shown in the following figure and table.

Parameter

Default

Description

Baudrate

19200

The rate at which data is sent between devices. (Options: 2400,

 

 

4800, 9600, 19200, 38400, 57600, 115200 bps, and Auto

 

 

detection).

 

 

Note that when AUTO is selected, you need to first press the

 

 

Enter key once to set the data rate and initialize the connection.

Time Out

0 minutes

If no input is received from the attached device after this interval

 

 

(in minutes), the current session is automatically closed. (Range:

 

 

0 -100 minutes; where 0 indicates disabled.)

Databits

8 bits

Sets the data bits of the RS-232 port. (Options: 7, 8)

Stopbits

1 bit

Sets the stop bits of the RS-232 port. (Options: 1, 2)

Parity

none

Sets the parity of the RS-232 port. (Options: none/odd/even)

Auto Refresh

0 sec.

Sets the interval before a console session will auto refresh the

 

 

console information, including Spanning Tree Information, Port

 

 

Configuration, Port Statistics, and RMON Statistics.

 

 

(Range: 0, or 5 - 255 seconds; where 0 indicates disabled.)

3-3

Image 55
Contents CheetahSwitch Workgroup-4508 Management Guide CheetaSwitch Workgroup-4508 RMA International Headquarters USA HeadquartersPage Contents Using the Web Agent Iii Appendix a TroubleshootingAdvanced Topics Appendix B Pin AssignmentsPage Configuration Options Managing the SwitchModem Connection Making Connections for System ConfigurationCheetahSwitch Workgroup-4508 Onsite ConnectionIn-Band Network Connection Management Guide Telnet ConnectionCheetahSwitch Workgroup-4508 Using the System Configuration Program Parameter Description Main MenuParameter Description Management GuideDisplaying System Information System Information MenuManagement Guide Displaying Version Information Management Setup MenuChanging the Network Configuration IP Configuration IP Connectivity Test Ping Access Host ConfigurationHttp Configuration Parameter Default Description CheetahSwitch Workgroup-4508 Configuring the Serial PortManagement Guide Assigning Snmp Parameters Configuring IP Trap Managers Configuring Community NamesConsole Login Configuration Using Tftp Protocol to Download Over the Network CheetahSwitch Workgroup-4508 Downloading System SoftwareConfiguring the Switch Enabled CheetahSwitch Workgroup-4508 Configuring Port ParametersUsing the Spanning Tree Algorithm Management Guide Viewing the Current Port ConfigurationPriority 32,768 Configuring Bridge STADisabled Configuring STA for PortsDisplaying the Current Bridge STA Displaying the Current STA for Ports Information. Port address table is cleared, and the port Igmp Multicast Filtering Management Guide Using a Mirror Port for AnalysisConfiguring Igmp Management Guide Broadcast Storm Control Refer to Network Monitor Menu / Static Unicast Address Table Port Priority Configuration Management Guide Configuring Traffic Classes802.1p Port Traffic Class Information 802.1Q Vlan Base Information Management Guide Configuring Virtual LANsMAX Vlan ID VID 802.1Q Vlan Current Table Information802.1Q Vlan Static Table Configuration Pvid 802.1Q Vlan Port ConfigurationMenu Description Monitoring the SwitchCheetahSwitch Workgroup-4508 Displaying Port Statistics Displaying Rmon Statistics Formed MAC Using the Address TableVlan ID assigned to this multicast group Multicast IP Parameter Management Guide Configuring Static Unicast AddressesVID MAC Logging Off the System Resetting the System Post Navigating the Web Browser Interface Using the Web AgentCheetahSwitch Workgroup-4508 Home Panel Display Console ConfigurationSTA SnmpVlan System Information Main Board Switch InformationIP Configuration Network ConfigurationCheetahSwitch Workgroup-4508 Access Host Snmp ConfigurationSnmp Administration Enable Trap Managers Management Guide Snmp CommunityWeb Upload Management Security ConfigurationFirmware Upgrade Options Change PasswordTftp Download Management Address Table Configuration Spanning Tree Spanning Tree InformationPorts Switch Parameter Default Description Management Guide Spanning Tree ConfigurationWhen the Switch Becomes Root Parameter Default Description Path Cost 100/19/4 STA Port ConfigurationBridge Capability Configuring Bridge MIB ExtensionsPort Priority Configuration Bridge SettingsPriority Port Traffic Class Information Vlan Basic Information Configuring VLANsVlan ID Management Guide Vlan Current TableVlan Static Table CheetahSwitch Workgroup-4508 Vlan Static ListVlan Static Membership by Port CheetahSwitch Workgroup-4508 Vlan Port Configuration Igmp Multicast Filtering Configuring IgmpPort Information Port MenusPort Configuration Port Statistics Port Mirroring ConfigurationEtherlike Statistics Sum of alignment errors and code errors frames received with Undersize Frames CheetahSwitch Workgroup-4508 Rmon StatisticsFCS or alignment error Broadcast Storm Control Spanning Tree Algorithm Advanced TopicsAssigning Ports to VLANs Virtual LANsPort Overlapping Management Guide Vlan ClassificationForwarding Tagged/Untagged Frames Igmp Snooping and IP Multicast Filtering Class-of-Service CoS SupportRemote Monitoring Snmp Management SoftwareCheetahSwitch Workgroup-4508 In-Band Connection Console ConnectionUpgrading Firmware via the Serial Port Loader DB9 Serial Port Pin Description Connection from Switch’s Serial Port to PC’s 9-Pin COM PortDB9 Port Pin Assignments Port Connection from Switchs Serial Port to PCs 25-Pin DTE PortSwitchs 9-Pin Ccitt Signal Modems Serial Port Pin COM Port Switchs 9-Pin Serial Null ModemES4508 E022000-R01