Logout (Default: 240 minutes)

This setting disconnects and logs out a user after the set period of no keyboard or mouse activity. To change the logout value, select the profile, then the logout time to change and press [Enter]. An input box will display. Type in a new logout time and press [Enter]. Valid times are 0 to 9999 minutes. A value of 0 (zero) disables the automatic logout function. If login is enabled for a KVM station, but the Logout time is set to zero, the user remains logged in until they manually log out using the [Ctrl] L command. (See Table 1, keyboard commands)

40ULTRAMATRIX E-SERIES MANUAL

Image 46
Contents Installation and Operations Manual Limited Warranty FCC/IC STATEMENTS, EU Declaration of Conformity Table of Contents Tables AppendicesPage About this manual IntroductionDisclaimer IntroductionUpgradability Security FeaturesFlexibility KVM compatibility On-screen display technologyCompatibility CPU compatibilityCable requirements Package contentsRose Electronics web site Models KVM station OverviewSystem Overview KVM Station Keyboard and MouseComputers ExpansionTwo expansion cards are Installed in the 4xE modelRS232 port Cabling System securitySite planning Installation Switch Installation Single UnitPre-Configuration procedure Ultramatrix E-SERIES Manual Switch Installation Multiple units BUS topology Starting computer Connecting the expansion unitsMaximum computers Ultramatrix E-SERIES Manual Connecting the computers Verifying the Video pathUltramatrix E-SERIES Manual Switch Installation Multiple units Ring topology Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Switch Installation Multiple units Split-BUS topology Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Configuration Menus Menu structureMain Menu KVMConfigure System menu System settings selectionsMaximum computers Default Starting computer number DefaultPC keyboard delay Default Fast Sun keyboard language Default US Appearance settings selectionsScreen saver time seconds Default 1800 seconds Background / Text color Default Cyan / BlackConfigure Computer menu Ultramatrix E-SERIES Manual Configure KVM menu BUSUltramatrix E-SERIES Manual Configure User menu Configure user menu Ultramatrix E-SERIES Manual Configure Profile menu Configure profile menuUltramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Configure Group menu Power System Status displayPos Position Ver VersionSave menu YESCommand Key Sequence Description Following instructions apply to all UltraMatrix switchesKeyboard commands OperationUser ID Password Computer select menu Connection successful to NT Server On Admin Share mode Disconnected from Payroll On Sharon Timed outSerial Port Connecting the Serial CableSetting up Windows HyperTerminal Serial port usage RS232Starting a serial communication session Serial menuOption 1. Change Starting Computer From card #1 only Serial menu optionsOption 2. Change the serial port baud rate Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Option 7. Save Changes Option 8. Exit Restart the UnitSwitching using the serial port Serial Device Support Serial device supportComputer Serial 9600,N,8,1 Maintenance and Repair ServiceService Information Technical SupportSafety SafetyGrounding Safety and EMC Regulatory StatementsServicing Ultramatrix E-SERIES Manual Troubleshooting TroubleshootingVideo fuzzy Mouse does not movePS/2 mouse gets out of sync Video not synchronized or wrong colorAppendices KVMAppendix B. General specifications CPU/KVM DB25FCPU Cables Rack Mount KitsCPU Appendix E. Disconnect Status Reasons Description Action Appendix F. KVM placement / conflicts Appendix G. Password jumper Appendix H. Diagnostic check / error messages Diagnostic DescriptionUltramatrix E-SERIES Manual Kernel halt error messages Message DescriptionAppendix I. Video distance table Appendix J. Rack mount Appendix K. Rack mount illustrationPage Page Stancliff Road Phone 281 Houston, Texas