SMC Networks EX500-GEN1 SI Unit Part Names, Display/Switch Setting, Default settings

Page 12

Display/Switch Setting (continued )

*1 : Remote control (SW1 all dip-switches off)

SMC's EX500 GW Unit will respond to the following Rockwell Automation BOOTP/DHCP Server commands.

Enable DHCP

Selecting this function will enable the EX500 GW Unit to retrieve its boot information from the BOOTP/DHCP Server. If DHCP is enabled the EX500 GW Unit will retrieve its boot information during the next power up.

Disable BOOTP/DHCP

Selecting this function will disable the EX500 to retrieve its boot information from the BOOTP/DHCP Server, and causes the EX500 to retain its current configuration during the next power up.

*2 : DHCP Mode (SW1 all dip-switches on)

The IP address is acquired via DHCP Server. The IP address is not saved and lost if the power to the EX500 unit is cycled.

*3 : Hardware Addressing

The IP address range is 192.168.0.1-192.168.0.254.

Default settings

At the time of factory shipment, the product is in "Remote Control Mode" and set to "Enable DHCP".

NOTE

If the stored IP address of an EX500 is not known, please go to the "DHCP Mode" section.

SI Unit Part Names

The SI unit is the unit to communicate with GW unit in combination with manifold valve. It can be used with SV series valves and VQC series valves.

In addition, this unit is able to operate solenoid valves, relays. etc. in combination with EX9 series general purpose output block. For how to use it, refer to section "EX9 Series General Purpose Output Block" ( page 32 ) in this manual.

1. SI unit for SV series valves ( EX500-S 01 )

SI unit for

SV series

2. SI unit for VQC series valves ( EX500-Q )

SI unit for VQC series

( EX500-Q01 )

Common to EX500-S 01/EX500-Q

No.

Name

Application

1

Communication

Connects the branch cable to Input unit ( branch cable

 

connector "C1" or "0"

with M12 connector ). ( Note1 )

 

 

 

2

Communication

Connects the branch cable from GW unit ( branch

 

connector "C2" or "1"

cable with M12 connector ). ( Note1 )

 

 

 

3

Power LED

Indicates the power supply status. ( Note2 )

 

 

 

4

Communication LED

Indicates the communication status with GW unit. ( Note2 )

 

 

 

Note1 : For wiring method, refer to subsection "Wiring" ( page 15 ) of section "EX500" in this manual.

Note2 : For display, refer to "Display" ( page 25 ) in section "SI Unit" in this manual.

20

21

Image 12
Contents Reduced wiring system Contents Do not operate beyond specification range Otherwise injury or failure can resultOtherwise accident caused by malfunction can result Otherwise injury can resultSafety System configuration generalProduct Summary Manifold valve with SI unit SV/VQC seriesDimensions unit mm Installation unit mmEX500 Part Names EX500 bodySpecification Basic specificationsHigher-level bus MappingWiring SpecificationWirings is explained in the following order Lower-level busWiring Communication wiringPower supply wiring Cable connectionBranch wiring Single power suppliesCable plug For GW unit Manifold valve Input unit manifold configuration For GW unit Input unit manifold configurationDisplay/Switch Setting Switch settingDisplay Display/Switch Setting Default settingsSI Unit Part Names SI unit for SV series valves EX500-SMounting/Wiring EX500-QMounting and removing methods of SI unit are as shown below Display SI unit for SV series valve EX500-SSI unit for VQC series valve EX500-Q Applicable valve seriesWhen only input blocks for M8 connector are connected Input Unit Manifold Part NamesInstallation Dimensions unit mmWhen only input blocks for M12 connector are connected Specifications for Input unitSensor wiring Lights off Sensor signal input OFF logicalCorrespondence between input number and input block Connect sensors to the sensorEX9-PE1 EX9-OET1/EX9-OET2 EX9-PE1Part name Application Output wiring EX9-OEP1/EX9-OEP2 output connectorsDimensions when general purpose output block is connected MountingEX9-PE1 power supply connector No.0 EX9-PE1 power input connector No.1EX9-OET1 EX9-OET2 EX9-OEP1 EX9-OEP2 PWROption Troubleshooting Overall systemEtherNet/IP compatible communication COM a D LED