SMC Networks EX500-GEN1 instruction manual Mounting/Wiring, EX500-Q

Page 13

Dimensions ( unit : mm )

1. SI unit for SV series valves ( EX500-S 01 )

79.4

28.6

68.5

54.5

39

15.5

2.SI unit for VQC series valves ( EX500-Q 01 )

Mounting/Wiring

The mounting and removing methods of SI unit are as shown below.

M330 : 4 pcs. ( Plus-minus slot round head screw )

Supply/exhaust block assembly

SI Unit for SV Series Valves ( EX500-S 01 )

 

PWR

 

 

COM

 

 

 

 

 

 

 

80.3

64.4

28

0

60

1

 

 

43.2

 

22.2

10.5

( EX500-Q 02 )

SI UNIT

PWR

COM

EX500

series

 

 

 

66

 

 

 

 

 

80.3

 

 

36

 

 

64.4

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

60

1

 

 

 

 

 

 

 

 

 

43.2

 

 

 

 

 

22.2

13.2

 

 

85.7

 

 

10.5

 

 

 

 

44

M3 10 : 2 pcs.

Supply/exhaust block

( Hexagon socket head cap

assembly

screw ( with spring washer ))

 

SI Unit for VQC Series Valves ( EX500-Q 01 )

NOTE

Holding with hand so that there will be no gap between SI unit and Air supply/exhaust block assembly, tighten the bolts. Be sure to tighten each bolt by specified tightening torque. ( Tightening torque : 0.6Nm )

Note 1

For branch wiring method, refer to subsection "Wiring" ( page 15 ) of section "EX500"

 

in this manual. As the power to output devices such as solenoid valve is supplied by

 

branch wiring ( branch cable with M12 connector ), there is no need to supply power

 

individually.

Note 2

For mounting/installation methods of solenoid valve, manifold, etc., refer to the

 

catalogs, instruction manuals, technical data, etc. of each valve series.

 

When connecting general purpose output block only, refer to subsection "Mounting"

 

( page 34 ) of section "EX9 Series General Purpose Output Block" in this manual.

22

23

Image 13
Contents Reduced wiring system Contents Otherwise injury or failure can result Do not operate beyond specification rangeOtherwise accident caused by malfunction can result Otherwise injury can resultSystem configuration general SafetyProduct Summary Manifold valve with SI unit SV/VQC seriesInstallation unit mm Dimensions unit mmEX500 Part Names EX500 bodyBasic specifications SpecificationHigher-level bus MappingSpecification WiringWirings is explained in the following order Lower-level busCommunication wiring WiringPower supply wiring Cable connectionSingle power supplies Branch wiringCable plug For GW unit Input unit manifold configuration For GW unit Manifold valve Input unit manifold configurationSwitch setting Display/Switch SettingDisplay Default settings Display/Switch SettingSI Unit Part Names SI unit for SV series valves EX500-SEX500-Q Mounting/WiringMounting and removing methods of SI unit are as shown below SI unit for SV series valve EX500-S DisplaySI unit for VQC series valve EX500-Q Applicable valve seriesInput Unit Manifold Part Names When only input blocks for M8 connector are connectedDimensions unit mm InstallationWhen only input blocks for M12 connector are connected Specifications for Input unitLights off Sensor signal input OFF logical Sensor wiringCorrespondence between input number and input block Connect sensors to the sensorEX9-OET1/EX9-OET2 EX9-PE1 EX9-PE1Part name Application EX9-OEP1/EX9-OEP2 output connectors Output wiringDimensions when general purpose output block is connected MountingEX9-PE1 power input connector No.1 EX9-PE1 power supply connector No.0PWR EX9-OET1 EX9-OET2 EX9-OEP1 EX9-OEP2Option Overall system TroubleshootingEtherNet/IP compatible communication COM a D LED