SMC Networks EX500-GEN1 instruction manual EX9-OET1/EX9-OET2 EX9-PE1, Part name Application

Page 18

EX9 Series General Purpose Output Block Part Names

The EX9 series general purpose output block is the unit to operate solenoid valve, relay, etc. in combination with VQC and SV ( tie-rod ) series valve and applicable SI unit. There are two types ---- one type is for low wattage load ( EX9-OET1 or EX9-OET2 ) that

outputs signals by receiving power supply from SI unit, and the other type is for high wattage load ( EX9-OEP1 or EX9-OEP2 ) that outputs signals by receiving power supply from outside. The type for high wattage load is used in combination with the power block ( EX9-PE1 ) connected with external power supply. As the low-wattage-load type is powered from SI unit, the wattage of load is limited to 1.0W ( Note ). For a load up to 12W, use the power block and the high-wattage-load type.

Note : When connected with EX500 series.

1. EX9-OET1/EX9-OET2/EX9-OEP1/EX9-OEP2

VQC series

 

 

SI unit for

 

 

VQC series

 

 

( EX500-Q 02 )

No.

Part name

Application

2. EX9-PE1

VQC series

 

 

SI unit for

 

 

general purpose

 

 

output block

 

 

( EX500-Q 02 )

No.

Part name

Application

1

Power supply connector

Unused

2

Power input connector

Supplies power for output devices. ( Note1 )

3

Power LED

Indicates the power supply status. ( Note2 )

Note1 : For wiring method, refer to subsection "Wiring" ( page 35 ) of section "EX9 Series General Purpose Output Block" in this manual.

Note2 : For display, refer to subsection "Display" ( page 39 ) in section "EX9 Series General Purpose Output Block" in this manual.

Dimensions ( unit : mm )

1. EX9-OET1/EX9-OET2/

2. EX9-PE1

EX9-OEP1/EX9-OEP2

 

1

Output connector

Connects with output device. ( Note1 )

 

 

 

2

Indicator LED

Indicates the output status. ( Note2 )

Note1 : For wiring method, refer to subsection "Wiring" ( page 35 ) of section "EX9 Series General Purpose Output Block" in this manual.

Note2 : For display, refer to subsection "Display" ( page 39 ) of section "EX9 Series General Purpose Output Block" in this manual.

72.6

21.2

21.2

 

59.8

 

43.2

 

22.2

21

26.7

80.3

PWR

59.8

43.2 22.2

21

26.7

32

33

Image 18
Contents Reduced wiring system Contents Otherwise accident caused by malfunction can result Do not operate beyond specification rangeOtherwise injury or failure can result Otherwise injury can resultProduct Summary SafetySystem configuration general Manifold valve with SI unit SV/VQC seriesEX500 Part Names Dimensions unit mmInstallation unit mm EX500 bodyHigher-level bus SpecificationBasic specifications MappingWirings is explained in the following order WiringSpecification Lower-level busPower supply wiring WiringCommunication wiring Cable connectionBranch wiring Single power suppliesCable plug For GW unit Manifold valve Input unit manifold configuration For GW unit Input unit manifold configurationDisplay/Switch Setting Switch settingDisplay SI Unit Part Names Display/Switch SettingDefault settings SI unit for SV series valves EX500-SMounting/Wiring EX500-QMounting and removing methods of SI unit are as shown below SI unit for VQC series valve EX500-Q DisplaySI unit for SV series valve EX500-S Applicable valve seriesWhen only input blocks for M8 connector are connected Input Unit Manifold Part NamesWhen only input blocks for M12 connector are connected InstallationDimensions unit mm Specifications for Input unitCorrespondence between input number and input block Sensor wiringLights off Sensor signal input OFF logical Connect sensors to the sensorEX9-PE1 EX9-OET1/EX9-OET2 EX9-PE1Part name Application Dimensions when general purpose output block is connected Output wiringEX9-OEP1/EX9-OEP2 output connectors MountingEX9-PE1 power supply connector No.0 EX9-PE1 power input connector No.1EX9-OET1 EX9-OET2 EX9-OEP1 EX9-OEP2 PWROption EtherNet/IP compatible communication TroubleshootingOverall system COM a D LED