SMC Networks EX500-GEN1 EX9-PE1 power supply connector No.0, EX9-PE1 power input connector No.1

Page 20

Wiring ( continued )

Power supply wiring

When combining EX9-OEP1 ( or EX9-OEP2 ) and EX9-PE1 and using external power supply, connect the power supply to the power input connector of EX9-PE1.

When selecting power supply, refer to "Handling precautions" ( page 3 ) in this manual.

EX9-PE1 power supply connector No.0

M12, 5-pin, reverse key, socket

Note

Keep the waterproof cap mounted on power supply connector No.0 while using

Pin alignment and connection drawing of the Power Supply Cable

48.1

M126.4 φ

30 5

50

EX9-PE1. This connector is prepared supplementarily and not used normally.

EX9-PE1 power input connector No.1

M12, 5-pin, reverse key, plug

 

2

1

1

2

 

5

 

 

5

 

3

4

4

3

 

Power input

 

Power supply

 

connector No.1

connector No.0

 

 

 

 

Pin No.

Power input connector No.1

 

Power supply connector No.0

1

Power supply for output devices ( 24VDC )

 

Power supply for output devices ( 24VDC )

 

 

 

 

2

Power supply for output devices ( 0V )

 

[ Power supply for output devices ( 0V ) ]

 

 

 

 

3

[ Power supply for sensor ( 24VDC ) ]

 

[ Power supply for sensor ( 24VDC ) ]

 

 

 

 

4

[ Power supply for sensor ( 0V ) ]

 

[ Power supply for sensor ( 0V ) ]

 

 

 

 

 

5

Ground

 

 

[ Ground ]

 

 

 

 

 

Note : Each signal of connector No.0 is connected to corresponding signal of connector No.1. The pins whose applications are shown in brackets [ ], are prepared supplementarily and not used normally.

 

EX9-AC -1

 

 

Pin No

Cable color : Signal name

1

Brown : Power supply for output ( 24VDC )

 

 

2

White : Power supply for output ( 0V )

 

 

3

Blue : [ Power supply to sensor ( 24VDC ) ]

 

 

4

Black : [ Power supply to sensor ( 0V ) ]

 

 

5

Gray : Ground ( PE )

 

 

12

5

43

Socket connector pin layout ( Reverse key )

36

37

Image 20
Contents Reduced wiring system Contents Do not operate beyond specification range Otherwise injury or failure can resultOtherwise accident caused by malfunction can result Otherwise injury can resultSafety System configuration generalProduct Summary Manifold valve with SI unit SV/VQC seriesDimensions unit mm Installation unit mmEX500 Part Names EX500 bodySpecification Basic specificationsHigher-level bus MappingWiring SpecificationWirings is explained in the following order Lower-level busWiring Communication wiringPower supply wiring Cable connectionCable plug Branch wiringSingle power supplies For GW unit Manifold valve Input unit manifold configuration For GW unit Input unit manifold configurationDisplay Display/Switch SettingSwitch setting Display/Switch Setting Default settingsSI Unit Part Names SI unit for SV series valves EX500-SMounting and removing methods of SI unit are as shown below Mounting/WiringEX500-Q Display SI unit for SV series valve EX500-SSI unit for VQC series valve EX500-Q Applicable valve seriesWhen only input blocks for M8 connector are connected Input Unit Manifold Part NamesInstallation Dimensions unit mmWhen only input blocks for M12 connector are connected Specifications for Input unitSensor wiring Lights off Sensor signal input OFF logicalCorrespondence between input number and input block Connect sensors to the sensorPart name Application EX9-PE1EX9-OET1/EX9-OET2 EX9-PE1 Output wiring EX9-OEP1/EX9-OEP2 output connectorsDimensions when general purpose output block is connected MountingEX9-PE1 power supply connector No.0 EX9-PE1 power input connector No.1EX9-OET1 EX9-OET2 EX9-OEP1 EX9-OEP2 PWROption Troubleshooting Overall systemEtherNet/IP compatible communication COM a D LED