SMC Networks EX500-GEN1 instruction manual EX9-OET1 EX9-OET2 EX9-OEP1 EX9-OEP2, Pwr

Page 21

Specification

1. EX9-OET1/EX9-OET2/ EX9-OEP1/EX9-OEP2

Item

 

Specification

 

Model No.

EX9-OET1

EX9-OET2

EX9-OEP1

EX9-OEP2

No. of output

 

2 points/unit

 

points

 

 

 

 

 

 

 

 

 

 

 

Output

P-ch MOS-FET

N-ch MOS-FET

P-ch MOS-FET

N-ch MOS-FET

method

( open drain )

( open drain )

( open drain )

( open drain )

 

 

 

 

 

Insulation

Optical isolation ( with SI unit )

Optical isolation ( with this unit )

method

( Note )

 

 

Display

1. EX9-OET1/EX9-OET2/EX9-OEP1/EX9-OEP2

Display

Description

 

 

0Lights on : Output ( OUT 0 ) is ON.

Lights off : Output ( OUT 0 ) is OFF.

1Lights on : Output ( OUT 1 ) is ON.

Lights off : Output ( OUT 1 ) is OFF.

Note : To be used in combination with EX9-PE1.

For detailed specifications, refer to the instruction manuals, technical data, etc. of EX9 series general purpose output block.

2. EX9-PE1

Item

Specification

Rated voltage

24VDC +10%, -5%

 

 

Supply current

3A Max.

 

 

2. EX9-PE1

PWR

Display

Description

PWR

Lights on : Power is supplied from external power

 

supply.

 

Lights off : Power is not supplied from external

 

power supply.

 

 

38

39

Image 21
Contents Reduced wiring system Contents Otherwise injury or failure can result Do not operate beyond specification rangeOtherwise accident caused by malfunction can result Otherwise injury can resultSystem configuration general SafetyProduct Summary Manifold valve with SI unit SV/VQC seriesInstallation unit mm Dimensions unit mmEX500 Part Names EX500 bodyBasic specifications SpecificationHigher-level bus MappingSpecification WiringWirings is explained in the following order Lower-level busCommunication wiring WiringPower supply wiring Cable connectionBranch wiring Single power suppliesCable plug For GW unit Input unit manifold configuration For GW unit Manifold valve Input unit manifold configurationDisplay/Switch Setting Switch settingDisplay Default settings Display/Switch SettingSI Unit Part Names SI unit for SV series valves EX500-SMounting/Wiring EX500-QMounting and removing methods of SI unit are as shown below SI unit for SV series valve EX500-S DisplaySI unit for VQC series valve EX500-Q Applicable valve seriesInput Unit Manifold Part Names When only input blocks for M8 connector are connectedDimensions unit mm InstallationWhen only input blocks for M12 connector are connected Specifications for Input unitLights off Sensor signal input OFF logical Sensor wiringCorrespondence between input number and input block Connect sensors to the sensorEX9-PE1 EX9-OET1/EX9-OET2 EX9-PE1Part name Application EX9-OEP1/EX9-OEP2 output connectors Output wiringDimensions when general purpose output block is connected MountingEX9-PE1 power input connector No.1 EX9-PE1 power supply connector No.0PWR EX9-OET1 EX9-OET2 EX9-OEP1 EX9-OEP2Option Overall system TroubleshootingEtherNet/IP compatible communication COM a D LED