SMC Networks EX500-GEN1 instruction manual Product Summary, Safety, System configuration general

Page 4

SAFETY ( continued )

Follow the instructions given below when handling your reduced wiring system. Otherwise a damage or failure to cause a malfunction can result.

Operate the reduced wiring system at the specified voltage.

Reserve space for maintenance.

Do not remove any name plate or label.

Do not drop, hit or apply an excessive shock to the unit.

Follow the specified tightening torque.

Do not apply any excessive force to cables by repeated bending, tensioning or placing a heavy object on the cables.

Connect wires and cables correctly.

Do not perform any wiring work while the power is on.

Do not use the reduced wiring system on the same wiring route as the power line or high voltage line.

Confirm the insulation of wiring.

Perform the power supply wiring by dividing into two lines ---- one is for power supply for output

and the other is for power supply for input and controlling GW/SI.

Take sufficient measures against noise such as noise filter when incorporating the reduced wiring system into a machine or equipment.

Mount a terminal plug or a waterproof cap on each unused M12 connector for input/output ( communication connector, communication ports A - D, and power supply for input and controlling GW/SI ).

Product Summary

System configuration general

EtherNet/IP

 

communication connector

GW unit

Power supply

 

connector cable

 

( 24VDC for solenoid

 

valves/output, 24VDC for

 

input and controlling GW/SI )

 

Manifold valve with SI unit

( SV/VQC series )

Branch cable

with M12 connector

Input unit manifold

Manifold valve with SI unit

( SV/VQC series )

Input unit manifold

Branch cable

with M12 connector

Take sufficient shielding measures when operating the product in any of the following places. ( 1 ) A place where noise due to static electricity etc. is generated

( 2 ) A place of high electric field strength

( 3 ) A place where exposure to radioactivity is possible

( 4 ) A place near power cable

Do not operate the product in a place where there is a source of surge.

Use a surge absorbing element built-in type to directly drive the load that generates surge voltage such as solenoid valve.

Prevent any foreign matter such as remnant of wires from getting inside the product when opening the station number switch protective cover.

Install the reduced wiring system in a place free from vibration and impact.

Operate the product in the specified ambient temperature range.

Do not use in a place to be affected by the radiant heat from a surrounding heat source.

Set the DIP switch and rotary switch by using a sharp-pointed watchmakers screwdriver etc.

Perform the maintenance regularly.

Conduct an appropriate functional inspection after completing the maintenance. Do not use chemicals such as benzin and thinner to clean the product.

The reduced wiring system is connected to various kinds of fieldbus realizes the reduced wiring and decentralized installation of I/O devices. The signals to/from fieldbus are exchanged by GW unit, and the signals to/from decentralized I/O devices are collected and delivered by GW unit.

The maximum number of connections of manifold valve/Input unit manifold is 16/branch x 4 branches = 64 points each for output and input.

As the cables with connectors are used for all wirings among devices, the system complies with the IP65 environment.

4

5

Image 4
Contents Reduced wiring system Contents Do not operate beyond specification range Otherwise injury or failure can resultOtherwise accident caused by malfunction can result Otherwise injury can resultSafety System configuration generalProduct Summary Manifold valve with SI unit SV/VQC seriesDimensions unit mm Installation unit mmEX500 Part Names EX500 bodySpecification Basic specificationsHigher-level bus MappingWiring SpecificationWirings is explained in the following order Lower-level busWiring Communication wiringPower supply wiring Cable connectionSingle power supplies Branch wiringCable plug For GW unit Manifold valve Input unit manifold configuration For GW unit Input unit manifold configurationSwitch setting Display/Switch SettingDisplay Display/Switch Setting Default settingsSI Unit Part Names SI unit for SV series valves EX500-SEX500-Q Mounting/WiringMounting and removing methods of SI unit are as shown below Display SI unit for SV series valve EX500-SSI unit for VQC series valve EX500-Q Applicable valve seriesWhen only input blocks for M8 connector are connected Input Unit Manifold Part NamesInstallation Dimensions unit mmWhen only input blocks for M12 connector are connected Specifications for Input unitSensor wiring Lights off Sensor signal input OFF logicalCorrespondence between input number and input block Connect sensors to the sensorEX9-OET1/EX9-OET2 EX9-PE1 EX9-PE1Part name Application Output wiring EX9-OEP1/EX9-OEP2 output connectorsDimensions when general purpose output block is connected MountingEX9-PE1 power supply connector No.0 EX9-PE1 power input connector No.1EX9-OET1 EX9-OET2 EX9-OEP1 EX9-OEP2 PWROption Troubleshooting Overall systemEtherNet/IP compatible communication COM a D LED