Seagate ST200FX0002, ST100FX0002, ST400FX0012, ST400FX0002 manual Dual port support

Page 53

11.2Dual port support

Pulsar XT.2 SAS drives have two independent ports. These ports may be connected in the same or different SCSI domains. Each drive port has a unique SAS address.

The two ports have the capability of independent port clocking (e.g. both ports can run at 6Gb/s or the first port can run at 6Gb/s while the second port runs at 3Gb/s.) The supported link rates are 1.5, 3.0, or 6.0 Gb/s.

Subject to buffer availability, the Pulsar XT.2 drives support:

Concurrent port transfers—The drive supports receiving COMMAND, TASK management transfers on both ports at the same time.

Full duplex—The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving frames on both ports.

Pulsar XT.2 SAS Product Manual, Rev. B

45

Image 53
Contents Standard Models Self-Encrypting Drive Models ST400FX0002ST400FX0012 ST200FX0002 ST100FX0002Revision history Contents Defect and error management Physical/electrical specificationsInstallation About self-encrypting drivesPage Pulsar XT.2 SAS Product Manual, Rev. B List of Figures Page Seagate Online Support and Services Seagate Technology support servicesScope Standards Applicable standards and reference documentationElectromagnetic compatibility Electromagnetic susceptibilityElectromagnetic compliance for the European Union Electromagnetic complianceAustralian C-Tick Korean KCCChina Restriction of Hazardous Substances RoHS Directive Reference documentsGeneral description Standard featuresReliability Media descriptionPerformance Programmable drive capacity Factory-installed optionsFormatted capacities Thin Provisioning Drive Configuration Internal drive characteristics Performance characteristicsPerformance characteristics Access timePerformance Format Mode Dcrt Bit IP Bit 400GB 200GB 100GBCaching write data Start/stop timeCache control Error rates Reliability specificationsEndurance Management Preventive maintenance Reliability and serviceData Retention Lifetime Endurance Management4 S.M.A.R.T Maximum processing delay Fully-enabled delayControlling S.M.A.R.T Performance impactThermal monitor Predictive failuresDrive Self Test DST State of the drive prior to testingDST failure definition ImplementationShort test Function Code 001b Short and extended testsExtended test Function Code 010b Log page entriesShipping Product warrantyProduct repair and return information StorageAC power requirements Physical/electrical specificationsPower specifications 400GB standard model DC power requirements DC power requirements200GB standard model DC power requirements 100GB standard model DC power requirements Power sequencing General DC power requirement notesConducted noise immunity Current profilesCurrent profiles for 200GB models 200GB models in 6Gb operation Power dissipation400GB models in 6Gb operation 100GB models in 6Gb operation Temperature a. OperatingEnvironmental limits Shock and vibration Relative humidityEffective altitude sea level a. Operating Recommended mounting ShockCorrosive environment Air cleanlinessVibration a. Operating-normal Mounting configuration dimensions 400GB models Mechanical specificationsWeight Pounds 100 grams Admin SP Controlled accessAbout self-encrypting drives Data encryptionRandom number generator RNG Default passwordDrive locking Data bandsPower requirements Authenticated firmware downloadSupported commands Cryptographic eraseSSD Physical format address descriptor Bit Byte Defect and error managementDrive internal defects/errors SAS system errors Drive error recovery proceduresBackground Media Scan Auto-ReallocationProtection Information PI Setting and determining the current Type LevelLevels of PI Identifying a Protection Information driveDrive orientation InstallationAir flow CoolingGrounding Drive mountingInterface requirements SAS featuresDual port support Supported commands Scsi commands supportedPersistent Reserve Read Capacity Write Inquiry data Mode Sense dataPage 14 1a 00 1a Mode Sense data for 400GB drivesMode Pages Mode Sense data for 200GB drivesMode Sense values for 100GB drives Miscellaneous features Miscellaneous operating features and conditionsMiscellaneous status SAS physical interfaceDatum B Section C C Section a a Connector requirements Physical characteristicsElectrical description Pin descriptionsPower Signal characteristicsSAS transmitters and receivers Ready LED OutLED drive signal SAS-2 Specification complianceDifferential signals General interface characteristicsNumerics IndexPage RNG See also cooling Page Americas Seagate Technology LLC