Table 10: 100GB standard model DC power requirements
Parameter |
|
| 100GB (6.0Gb) |
| |
|
|
|
|
| |
Regulation |
| ±5% | ±5% |
| |
|
|
|
|
|
|
Voltage |
| +5V | +12V |
| |
|
|
|
|
|
|
|
|
| Current (A) | Current (A) | Power (W) |
|
|
|
|
|
|
Average idle current | DC | 0.40 | 0.17 | 4.04 | |
|
|
|
|
|
|
Maximum starting current |
|
|
|
| |
| (peak DC) DC | 3σ | 1.09 | 0.31 |
|
| (peak AC) AC | 3σ | 1.16 | 0.73 |
|
Delayed start (max) DC | 3σ | 0.43 | 0.18 | 4.31 | |
|
|
|
|
|
|
Peak operating current (random read): |
|
|
|
| |
| Typical DC | DC | 0.46 | 0.21 | 4.82 |
|
|
|
|
|
|
| Maximum DC | 3σ | 0.49 | 0.23 | 5.21 |
|
|
|
|
|
|
| Maximum (peak) DC | 3σ | 0.80 | 0.72 |
|
Peak operating current (random write) |
|
|
|
| |
| Typical DC | DC | 0.45 | 0.25 | 5.25 |
|
|
|
|
|
|
| Maximum DC | 3σ | 0.49 | 0.26 | 5.57 |
|
|
|
|
|
|
| Maximum (peak) DC | 3σ | 0.71 | 0.54 |
|
Peak operating current (sequential read) |
|
|
|
| |
| Typical DC | DC | 0.54 | 0.28 | 6.06 |
|
|
|
|
|
|
| Maximum DC | 3σ | 0.58 | 0.29 | 6.38 |
|
|
|
|
|
|
| Maximum (peak) DC | 3σ | 0.80 | 0.58 |
|
Peak operating current (sequential write) |
|
|
|
| |
| Typical DC | DC | 0.53 | 0.36 | 6.97 |
|
|
|
|
|
|
| Maximum DC | 3σ | 0.57 | 0.37 | 7.29 |
|
|
|
|
|
|
| Maximum (peak) DC | 3σ | 0.82 | 0.82 |
|
|
|
|
|
|
|
[1]Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these values. Power supply at nominal voltage. N (number of drives tested) = 6, 60 Degrees C ambient.
[2]For +12 V, a
[3]See +12V current profile in Figure 4 (for 400GB models) and Figure 5 (for 200GB models).
[4]See +12V current profile in Figure 6 (for 100GB models).
[5]This condition occurs after OOB and Speed Negotiation completes but before the drive has received the Notify Spinup primitive.
[6]See paragraph 7.3.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and transient response.
Pulsar XT.2 SAS Product Manual, Rev. B | 25 |