10.3Drive mounting
Mount the drive using the bottom or side mounting holes. If mounting the drive using the bottom holes, ensure that you do not physically distort the drive by attempting to mount it on a stiff,
The allowable mounting surface stiffness is 80 lb/in (14.0 N/mm). The following equation and paragraph define the allowable mounting surface stiffness:
K x X = F < 15lb = 67N
where K is the mounting surface stiffness (units in lb/in or N/mm) and X is the
10.4Grounding
Signal ground (PCBA) and case ground are connected together in the drive and cannot be separated by the user. The equipment in which the drive is mounted is connected directly to the drive with no electrically isolat- ing shock mounts. If it is desired for the system chassis to not be connected to the drive ground, the systems integrator or user must provide a nonconductive (electrically isolating) method of mounting the drive in the host equipment.
Increased radiated emissions may result if designers do not provide the maximum surface area ground con- nection between system ground and drive ground. This is the system designer’s and integrator’s responsibility.
Pulsar XT.2 SAS Product Manual, Rev. B | 43 |