4.5Formatted capacities
Standard OEM models are formatted to 512 bytes per block. The block size is selectable at format time and must be a multiple of 4 bytes. Users having the necessary equipment may modify the data block size before issuing a FORMAT UNIT command and obtain different formatted capacities than those listed.
To provide a stable target capacity environment and at the same time provide users with flexibility if they choose, Seagate recommends product planning in one of two modes:
Seagate designs specify capacity points at certain block sizes that Seagate guarantees current and future products will meet. We recommend customers use this capacity in project planning, as it ensures a stable operating point with backward and forward compatibility from generation to generation. The current guaranteed operating points for this product are shown below. The Capacity stated is identical when the drive is formatted with or without PI enabled.
Table 1: | Formatted Capacity LBA Count |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
Capacity (LBAs) |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
LBA | 400GB |
| 200GB |
| 100GB |
| |||
|
|
|
|
|
|
|
|
| |
Size | Decimal |
| Hex | Decimal |
| Hex | Decimal |
| Hex |
|
|
|
|
|
|
|
|
|
|
512 | 781,422,768 |
| 2E9390B0h | 390,721,968 |
| 1749F1B0h | 195,371,568 |
| BA52230h |
|
|
|
|
|
|
|
|
|
|
520 | 764,871,800 |
| 2D970478h | 382,435,904 |
| 16CB8240h | 191,217,952 |
| B65C120h |
|
|
|
|
|
|
|
|
|
|
524 | 754,677,072 |
| 2CFB7550h | 377,338,536 |
| 167DBAA8h | 188,669,272 |
| B3EDD58h |
|
|
|
|
|
|
|
|
|
|
528 | 743,833,040 |
| 2C55FDD0h | 371,916,520 |
| 162AFEE8h | 185,958,264 |
| B157F78h |
|
|
|
|
|
|
|
|
|
|
4096 | 97,677,846 |
| 5D27216h | 48,840,246 |
| 2E93E36h | 24,421,446 |
| 174A446h |
|
|
|
|
|
|
|
|
|
|
4160 | 96,153,847 |
| 5BB30F7h | 48,076,924 |
| 2DD987Ch | 24,038,462 |
| 16ECC3Eh |
|
|
|
|
|
|
|
|
|
|
4192 | 95,419,848 |
| 5AFFDC8h | 47,709,924 |
| 2D7FEE4h | 23,854,962 |
| 16BFF72h |
|
|
|
|
|
|
|
|
|
|
4224 | 94,696,970 |
| 5A4F60Ah | 47,348,485 |
| 2D27B05h | 23,674,243 |
| 1693D83h |
|
|
|
|
|
|
|
|
|
|
4.6Programmable drive capacity
Using the MODE SELECT command, the drive can change its capacity to something less than maximum. See the MODE SELECT (6) parameter list table in the SAS Interface Manual, part number 100293071. A value of zero in the Number of Blocks field indicates that the drive will not change the capacity it is currently formatted to have. A number other than zero and less than the maximum number of LBAs in the Number of Blocks field changes the total drive capacity to the value in the Number of Blocks field. A value greater than the maximum number of LBAs is rounded down to the maximum capacity.
4.7Factory-installed options
OEMs may order the following items which are incorporated at the manufacturing facility during production or packaged before shipping. Some of the options available are (not an exhaustive list of possible options):
•Other capacities can be ordered depending on sparing scheme and LBA size requested.
•
•The Safety and Regulatory Agency Specifications, part number 75789512, is usually included with each standard OEM drive shipped, but extra copies may be ordered.
8 | Pulsar XT.2 SAS Product Manual, Rev. B |