Teledyne 3160 manual Appendix Material Safety Data Sheet, Date Prepared 2/12/96

Page 62

Appendix

A.4 Material Safety Data Sheet I

Section I – Product Identification

Product Name: Micro-Fuel Cells and Super Cells, all classes except A-2C, A-3, and A-5.

Electrochemical Oxygen Sensors, all classes except R-19. Mini-Micro-Fuel Cells, all classes.

Manufacturer: Teledyne Analytical Instruments

Address: 16830 Chestnut Street, City of Industry, CA 91749

Phone: (818) 961-9221

Customer Service: Extension 222

Environmental Health

and Safety: Extension 230

Date Prepared : 2/12/96

Section II – Hazardous Ingredients/Composition

Material or

 

 

 

 

 

Component

C.A.S. #

Quantity

OSHA PEL

ACGIH

TLV

 

 

 

 

 

 

 

 

 

 

 

Lead (Pb)

7439-92-1

3–20 gms

0.05 mg/m3

0.15 mg/m3

Potassium Hydroxide1310-58-3 1–5 ml

None 2 mg/m3

 

 

Solution 15% (KOH)

 

 

 

 

 

Section III – Physical/Chemical Characteristics

 

Material

Boiling

Specific Vapor

Melting Density

Evap. Solubility

Odor

 

Appearance

 

or Compo-

Point (°C) Gravity Pres-

Point

Rate

in Water

 

 

 

 

nent

 

sure

(°C)

 

 

 

 

 

 

 

1744

11.34

na

na

Insoluble

Solid, silver

 

 

Lead

 

na

328

 

 

gray, odorless

 

 

1320

2.04

na

na

Complete

White or

 

Potassium

 

na

360

 

 

slightly

 

Hydroxide

 

 

 

 

 

yellow,

 

 

 

 

 

 

 

no odor

 

 

 

 

 

 

 

A-4

 

TELEDYNE ANALYTICAL INSTRUMENTS

 

 

 

Image 62
Contents Model Copyright 1999 Teledyne Analytical Instruments Iii Table of Contents Maintenance & Troubleshooting AppendixTeledyne Analytical Instruments Variable Features FeaturesFixed Features IntroductionIntroduction 3160DA Dual fuel cell Introduction ComponentsOptions and Model Numbers Introduction Applications Operational Theory Principles of OperationMajor Components Operational Theory Micro-Fuel Cell Sensor Sample SystemOperational Theory Electronics and Signal Processing Model 3160 flow schematicOperational Theory Analog signal output offset Identifier Range Scale Voltage CurrentmADefaults Programmable Options Front Panel InstallationUnpacking the Analyzer Qty DescriptionRear Panel Analyzer front and rear panels Instrument Air Compressed Air Fitting Installation Gas Line ConnectionsSpan Gas Sample GasSensor Installation Electrical Connections Voltage Selection 3160 Rear PanelFuse Changing Removing the Voltage CardFuse Replacement Installation Checklist 3 RS-232 Serial Digital PortOperations Front Panel ControlsCell Output Factor Span Factor Modes of OperationSpinning Wheel Operations Changing Passwords For Remote Monitoring and Control Uled Span in ProgressOperations Cold Start-Up Operations Calibration Zeroing Operations Operations Calibration Using Span Gas Operations Operations Operations Select Active Sensor Two Cells Only Setup Operations Operations O2 Range Set-Up AccptOperations Set-Up Alarms Cold StartOperations Operations Logger Set-Up Operations Operations Set-Up Clock Functions Accpt Teledyne Analytical Instruments Operations Operations System Statistics Comm. Std. for 1200B Bell USA/CCITT Baud rateAscii Data Bits 7 or Stop Bits 1 or Operations Operations Sensor Maintenance Maintenance & TroubleshootingRoutine Maintenance Scrubber MaintenanceTroubleshooting Symptom Cause CorrectionMaintenance & Troubleshooting Symptom Cause Correction Maintenance & Troubleshooting Appendix SpecificationsOperating Temperature0-50C 32 -122 F Altitude 1,609 m Relative Humidy Up to 99% Teledyne Analytical InstrumentsAppendix Recommended Spare Parts List Drawing ListDate Prepared 2/12/96 Appendix Material Safety Data SheetCustomer Service Extension Environmental Health Material or Component S. # QuantitySection IV Fire and Explosion Hazard Data Protective measures during cell replacement ExposureSection Viii Control Measures Address Product NameManufacturer PhoneExposure limits Osha PEL Signs/symptoms of exposurePrimary route of entry Effects of overexposure IngestionProtective measures Disposal