1.2Components

The analyzer is designed to mount in a standard 19-inch rack. All of the opera- tional controls are easily accessed through the front panel. The analyzer contains each of the following:

Analysis Section

Single or Dual Electrochemical Micro-Fuel Cell

Sample System

Power Supply

Microcontroller Module

LED Display

The front panel consists of:

LED Display

LCD Display with Touch Panel

Micro-Fuel Cell Access Panel

Flowmeter and flow set knob

The back panel ports are:

Gas Inlet/Outlet Ports

Electrical Connections

1.3Options and Model Numbers

The 3160 is available with the following standard options, which are designated by a descriptive suffix on the model number. Most of the options can be combined.

3160SA Single fuel cell.

3160SB Single fuel cell and oxygen scrubber

• 3160DA

Dual fuel cell

3160DB Dual fuel cell and oxygen scrubber

3160SAS Single cell and stainless steel cell block

3160SBS Single cell, stainless steel cell block, and oxygen scrubber

3160DAS Dual cell and stainless steel cell block

3160DBS Dual cell, stainless steel cell block, and oxygen scrubber

TELEDYNE ANALYTICAL INSTRUMENTS

1-3

Image 9
Contents Model Copyright 1999 Teledyne Analytical Instruments Iii Table of Contents Appendix Maintenance & TroubleshootingTeledyne Analytical Instruments Fixed Features FeaturesVariable Features IntroductionIntroduction Introduction Components Options and Model Numbers3160DA Dual fuel cell Introduction Applications Principles of Operation Operational TheoryMajor Components Sample System Operational Theory Micro-Fuel Cell SensorOperational Theory Model 3160 flow schematic Electronics and Signal ProcessingOperational Theory Identifier Range Scale Voltage CurrentmA Analog signal output offsetDefaults Programmable Options Unpacking the Analyzer InstallationFront Panel Qty DescriptionRear Panel Analyzer front and rear panels Span Gas Installation Gas Line ConnectionsInstrument Air Compressed Air Fitting Sample GasSensor Installation Electrical Connections 3160 Rear Panel Voltage SelectionRemoving the Voltage Card Fuse ChangingFuse Replacement 3 RS-232 Serial Digital Port Installation ChecklistFront Panel Controls OperationsModes of Operation Spinning WheelCell Output Factor Span Factor Operations Uled Span in Progress Changing Passwords For Remote Monitoring and ControlOperations Cold Start-Up Operations Calibration Zeroing Operations Operations Calibration Using Span Gas Operations Operations Operations Select Active Sensor Two Cells Only Setup Operations Accpt Operations O2 Range Set-UpCold Start Operations Set-Up AlarmsOperations Operations Logger Set-Up Operations Operations Set-Up Clock Functions Accpt Teledyne Analytical Instruments Operations Operations System Statistics Baud rate Ascii Data Bits 7 or Stop Bits 1 orComm. Std. for 1200B Bell USA/CCITT Operations Operations Routine Maintenance Maintenance & TroubleshootingSensor Maintenance Scrubber MaintenanceSymptom Cause Correction TroubleshootingMaintenance & Troubleshooting Symptom Cause Correction Maintenance & Troubleshooting Specifications Operating Temperature0-50C 32 -122 FAppendix Teledyne Analytical Instruments Altitude 1,609 m Relative Humidy Up to 99%Drawing List Appendix Recommended Spare Parts ListCustomer Service Extension Environmental Health Appendix Material Safety Data SheetDate Prepared 2/12/96 Material or Component S. # QuantitySection IV Fire and Explosion Hazard Data Exposure Protective measures during cell replacementSection Viii Control Measures Manufacturer Product NameAddress PhonePrimary route of entry Signs/symptoms of exposureExposure limits Osha PEL Effects of overexposure IngestionDisposal Protective measures