Perle Systems S-1110DPP Fiber Redundancy Switch Dual fiber models only, Redundant Primary Switch

Page 15

Fiber Redundancy (Switch 7)

Dual fiber models only

Switch Position

Mode

 

 

Up (default)

Disabled

 

 

Down

Enabled

 

 

Disabled: When this feature is disabled, both fiber ports will operate as independent ports on a switch. Normal switch rules and functions will apply.

Enabled: When this feature is enabled, fiber port 1 will be the primary active fiber connection port and fiber port 2 will be in standby and in an inactive state. Should a loss of link occur on fiber port 1, fiber port 2 will be activated within 50 ms. The MAC caching table for fiber port 2 will be cleared and the switch will begin to re-learn Mac address routing. See Redundant Primary for information on link connections.

Redundant Primary (Switch 8)

Note: This switch is used in conjunction with the Fiber Redundancy feature to determine the behaviour after link restoration.

Switch Position

Mode

 

 

Up (default)

Disabled

 

 

Down

Enabled

 

 

Disabled: Following the loss of link on fiber port 1 and the activation of fiber port 2, fiber port 2 will remain the primary port until its link is lost at which time a switch over to fiber port 1 will occur.

Enabled: Fiber port 1 will be designated as the Primary fiber port. If a loss of link occurs on fiber port 1 which causes a switch over to fiber port 2, the S-1110P will monitor fiber port 1 for link restoration. Once the link is re-established and remains so for 6 seconds, fiber port 1 will be re-activated and fiber port 2 will be put back into stand-by-mode.

Perle PoE/PoE+ 10/100/1000 Ethernet Media Converter

15

Installation Guide

 

Image 15
Contents 1110P 1110PP 1110DP 1110DPP Installation GuidePort Models OverviewDual Copper / PoE DP Connector Mode Wavelength Port Models SFP Port Models SPFAuto-MDIX Jumper Settings InstallationPoE+ Power Sourcing PinoutsUTP copper Power PoEPowering Options Jumper Settings DIP Switches BankBank Switch Position Copper DIP Switch Settings BankAuto Negotiation copper Switch Link Mode SwitchSwitch Position Fiber Port Fiber Fault Alert SwitchDuplex copper Switch Switch Position Copper portIllustration of the FFA Speed copper Switch Auto Fiber Negotiation SwitchSwitch Fiber Position Mbps Up default Auto Down Off Switch Position 1 Switch Position 2 Type Loopback Fiber-1 Switch Loopback Fiber-2 SwitchSwitch Position Mode Redundant Primary Switch Fiber Redundancy Switch Dual fiber models onlyInstalling the SFP Fiber Module Installing the Duplex Fiber CableInstalling the Simplex Fiber Cable Installing the Copper Cable Grounding the Media ConverterAttaching the Grounding Lug Attaching the Power cord strain relief clip Powering up the Perle Media ConverterOperation Status LEDLED Pattern Error conditions Other Features Auto-MDIXPause Ieee 802.3xy Method TroubleshootingGeneral No connectivityNo Power to the PD Fiber Optic Specifications Technical Specifications1110PP-S1SC120U Min Ethernet Copper Cabling Requirements Fiber Cabling RequirementsCompliance Information EN 55022, Class a EN 55024, Class a Laser Safety IECWarranty / Registration Contacting Technical SupportCopyright