Fiber Redundancy (Switch 7)
Dual fiber models only
Switch Position | Mode |
|
|
Up (default) | Disabled |
|
|
Down | Enabled |
|
|
Disabled: When this feature is disabled, both fiber ports will operate as independent ports on a switch. Normal switch rules and functions will apply.
Enabled: When this feature is enabled, fiber port 1 will be the primary active fiber connection port and fiber port 2 will be in standby and in an inactive state. Should a loss of link occur on fiber port 1, fiber port 2 will be activated within 50 ms. The MAC caching table for fiber port 2 will be cleared and the switch will begin to
Redundant Primary (Switch 8)
Note: This switch is used in conjunction with the Fiber Redundancy feature to determine the behaviour after link restoration.
Switch Position | Mode |
|
|
Up (default) | Disabled |
|
|
Down | Enabled |
|
|
Disabled: Following the loss of link on fiber port 1 and the activation of fiber port 2, fiber port 2 will remain the primary port until its link is lost at which time a switch over to fiber port 1 will occur.
Enabled: Fiber port 1 will be designated as the Primary fiber port. If a loss of link occurs on fiber port 1 which causes a switch over to fiber port 2, the
Perle PoE/PoE+ 10/100/1000 Ethernet Media Converter | 15 |
Installation Guide |
|