Perle Systems S-1110P manual Installing the SFP Fiber Module, Installing the Duplex Fiber Cable

Page 16

Installing the SFP Fiber Module

SFP models only.

1.Locate the appropriate fiber module and insert the SFP into the opening on the front of the media converter.

2.Ensure the SFP module is properly seated. The release latch of the SPF fiber transceiver must be in the closed (up) position before insertion.

3.The SFP module may be inserted before or after applying power to the media converter.

4.Proceed with cable connections.

Installing the Duplex Fiber Cable

1.Locate a 1000Base-X compliant duplex (2 strands) fiber cable with appropriate connectors.

2.Connect the fiber cables from one media converter to the other media converter/switch/fiber device ensuring that the RX and TX are reversed (crossed) at the opposite end.

Installing the Simplex Fiber Cable

1.Locate a 1000Base-X compliant simplex (1 strand) fiber cable with appropriate connectors. Ensure that the TX wavelength matches the RX wavelength at the other end and the RX wavelength matches the TX wavelength at the other end.

2.Connect the fiber cable from one media converter to the other media converter/switch/fiber device.

16

Perle PoE/PoE+ 10/100/1000 Ethernet Media Converter

 

Installation Guide

Image 16
Contents Installation Guide 1110P 1110PP 1110DP 1110DPPOverview Port ModelsDual Copper / PoE DP Connector Mode Wavelength Port Models SPF Port Models SFPInstallation Auto-MDIX Jumper SettingsPower Sourcing Pinouts UTP copper PowerPoE PoE+Powering Options Jumper Settings Bank DIP SwitchesBank DIP Switch Settings Bank Auto Negotiation copper SwitchLink Mode Switch Switch Position CopperFiber Fault Alert Switch Switch Position Fiber PortSwitch Position Copper port Duplex copper SwitchIllustration of the FFA Auto Fiber Negotiation Switch Speed copper SwitchSwitch Fiber Position Mbps Up default Auto Down Off Loopback Fiber-1 Switch Loopback Fiber-2 Switch Switch Position 1 Switch Position 2 TypeSwitch Position Mode Fiber Redundancy Switch Dual fiber models only Redundant Primary SwitchInstalling the Duplex Fiber Cable Installing the SFP Fiber ModuleInstalling the Simplex Fiber Cable Grounding the Media Converter Installing the Copper CableAttaching the Grounding Lug Powering up the Perle Media Converter Attaching the Power cord strain relief clipStatus LED OperationLED Pattern Error conditions Auto-MDIX Other FeaturesPause Ieee 802.3xy Troubleshooting GeneralNo connectivity MethodNo Power to the PD Technical Specifications Fiber Optic Specifications1110PP-S1SC120U Min Fiber Cabling Requirements Ethernet Copper Cabling RequirementsEN 55022, Class a EN 55024, Class a Laser Safety IEC Compliance InformationContacting Technical Support Warranty / RegistrationCopyright