Down
Down
PSE disabled
These switches must be set in order to enable the power sourcing function and to indicate the type of device detection required. If the device type is unknown, the default should be used as per IEEE802.3af/at standards.
Enabled: When enabled, the media converter will perform Power Sourcing Equipment (PSE) functions as per IEEE802.3af (POE) or
Disabled: When disabled the media converter will not perform PSE functions.
PD Power Reset 1 (Switch 3)
PD Power Reset 2 (Switch 6) (dual copper models only)
Switch Position | Mode |
|
|
Up (default) | Disabled |
|
|
Down | Enabled |
|
|
Disabled: When disabled, the loss of fiber link has no effect on PSE power to the PD device.
Enabled: When enabled, if the media converter detects loss of link on any fiber port it will turn off PSE output power to the PD device connected to copper port 1. After 2 seconds, the media converter will restore power to the PD and the power will remain on until one of the fiber links transitions from the link up to link down state.
Disabled: When disabled the media converter will not perform PSE functions.
14 | Perle PoE/PoE+ 10/100/1000 Ethernet Media Converter |
| Installation Guide |