Perle Systems S-1110PP, S-1110DPP manual Error conditions

Page 20

SPD-(Copper Port 1/2)

Green – 1000 Mbps

Orange – 100 Mbps

Off – 10 Mbps (if link is currently established)

FDC-1/2 (Duplex on Copper 1/2)

On – Full Duplex Mode

Off – Half Duplex Mode

LKC-1/2 (Link Status on Copper port 1/2)

On – Copper link is present

Off – No copper link present

Blinking (slow) – Copper link appears functional – Copper link has been brought down by Smart Link Pass-Through.

Blinking (fast) – Copper link up and receiving data

PSE-1/2

Solid Green (Active) – The PSE has successfully detected a compliant PD and is applying power over the UTP.

Solid Orange (Inactive) – The PSE is not active. The PSE has been configured to provide power, however

a compliant PD is not detected - no power applied

a PSE has turned off power for Reset function

Off – (Disabled) The PSE function is disabled in the configuration.

Error conditions

A blinking red light is an error condition. The led light will cycle with a 3 second stop interval between the error condition code.

PSE-1 / 2 LED

 

1 blink

PD Capacitance too high

2 blinks

PD Resistance too low or short circuit

3 blinks

PD Resistance too high

20

Perle PoE/PoE+ 10/100/1000 Ethernet Media Converter

 

Installation Guide

Image 20
Contents Installation Guide 1110P 1110PP 1110DP 1110DPPOverview Port ModelsDual Copper / PoE DP Connector Mode Wavelength Port Models SPF Port Models SFPInstallation Auto-MDIX Jumper SettingsPower Sourcing Pinouts UTP copper PowerPoE PoE+Powering Options Jumper Settings Bank DIP SwitchesBank DIP Switch Settings Bank Auto Negotiation copper SwitchLink Mode Switch Switch Position CopperFiber Fault Alert Switch Switch Position Fiber PortIllustration of the FFA Duplex copper SwitchSwitch Position Copper port Switch Fiber Position Mbps Up default Auto Down Off Speed copper SwitchAuto Fiber Negotiation Switch Loopback Fiber-1 Switch Loopback Fiber-2 Switch Switch Position 1 Switch Position 2 TypeSwitch Position Mode Fiber Redundancy Switch Dual fiber models only Redundant Primary SwitchInstalling the Simplex Fiber Cable Installing the SFP Fiber ModuleInstalling the Duplex Fiber Cable Attaching the Grounding Lug Installing the Copper CableGrounding the Media Converter Powering up the Perle Media Converter Attaching the Power cord strain relief clipLED Pattern OperationStatus LED Error conditions Pause Ieee 802.3xy Other FeaturesAuto-MDIX Troubleshooting GeneralNo connectivity MethodNo Power to the PD Technical Specifications Fiber Optic Specifications1110PP-S1SC120U Min Fiber Cabling Requirements Ethernet Copper Cabling RequirementsEN 55022, Class a EN 55024, Class a Laser Safety IEC Compliance InformationCopyright Warranty / RegistrationContacting Technical Support