Omega Engineering OME-PIO-D96 manual Vcc Gnd

Page 25

CN2/CN3/CN4: 50-pin of flat-cable connector (for Port3 ~ Port11)

Pin Number

Description

Pin Number

Description

1

P5C7/P8C7/P11C7

2

GND

3

P5C6/P8C6/P11C6

4

GND

5

P5C5/P8C5/P11C5

6

GND

7

P5C4/P8C4/P11C4

8

GND

9

P5C3/P8C3/P11C3

10

GND

11

P5C2/P8C2/P11C2

12

GND

13

P5C1/P8C1/P11C1

14

GND

15

P5C0/P8C0/P11C0

16

GND

17

P4B7/P7B7/P10B7

18

GND

19

P4B6/P7B6/P10B6

20

GND

21

P4B5/P7B5/P10B5

22

GND

23

P4B4/P7B4/P10B4

24

GND

25

P4B3/P7B3/P10B3

26

GND

27

P4B2/P7B2/P10B2

28

GND

29

P4B1/P7B1/P10B1

30

GND

31

P4B0/P7B0/P10B0

32

GND

33

P3A7/P6A7/P9A7

34

GND

35

P3A6/P6A6/P9A6

36

GND

37

P3A5/P6A5/P9A5

38

GND

39

P3A4/P6A4/P9A4

40

GND

41

P3A3/P6A3/P9A3

42

GND

43

P3A2/P6A2/P9A2

44

GND

45

P3A1/P6A1/P9A1

46

GND

47

P3A0/P6A0/P9A0

48

GND

49

VCC

50

GND

All signals are TTL compatible.

OME-PIO-D96 User Manual (Ver.1.1, Mar/2003)

---- 23

Image 25
Contents User’sGuide Mexico CanadaBenelux Czech RepublicOME-PIO-D96 Table of Contents Introduction FeaturesOrder Description SpecificationsOptions Product Check List PCI Data Acquisition FamilyOME-PISO-series cost-effective generation, isolated cards Board Layout Hardware configurationI/O port Location Enable I/O OperationRefer to DEMO1.C for demo program D/I/O Architecture Make sure the initial level is High or Low Interrupt OperationINTCHAN3 Interrupt Block Diagram of OME-PIO-D96INTCHAN0/1/2/3 COUNTL++ Initialhigh, activelow Interrupt sourceInitiallow, activehigh Interrupt source Muliti Interrupt Source Read all interrupt state OME-DB-37 Daughter BoardsOME-DN-37 & OME-DN-50 OME-DB-8125OME-ADP-37/PCI & OME-ADP-50/PCI OME-DB-24P/24PD Isolated Input Board OME-DB-24R/24RD Relay Board OME-DB-24PR/24POR/24C Daughter Boards Comparison Table Pin Assignment All signals are TTL compatibleVCC GND Resource-allocated information How to Find the I/O AddressOME-PIO/PISO identification information PC’s physical slot informationPIODriverInit&wBoards, wSubVendor,wSubDevice,wSubAux PIODriverInitWSubVendor=0x80 wSubDevice=1 wSubAux=0x10 /* for PIOD96 Current sinking Enable all D/I/O operation of card0 PIOGetConfigAddressSpaceEnable all D/I/O operation of card1 ShowPIOPISOwSubVendor,wSubDevice,wSubAux ShowPIOPISOSlot5 0x0A Slot6 0x08 Slot7 0x09 Slot8 0x07 Assignment of I/O AddressAddress Read Write I/O Address MapAUX Control Register RESET\ Control RegisterAUX data Register Aux Status Register INT Mask Control RegisterINV3 INV2 INV1 INV0 Interrupt Polarity Control Register7 I/O Selection Control Register Read/Write 8-bit data Register Demo program How to install software & utility?Piopiso PIOPISO.EXE for Windows DEMO1 DEMO2 DEMO3 COUNTL++ DEMO4 COUNTL++ DEMO5 CNTL1=CNTL2=CNTL3=CNTL4=0 Page WARRANTY/DISCLAIMER Temperature