6 PRE-OPERATIONAL CHECK

The CL526 portable calibrator is powered by four Ni-MH rechargeable batteries.

The external battery charger, supplied as standard, may be ordered for either 110/120 Vac or 220/240 Vac power source. To modify the charger’s power voltage follow the instructions in par. 8.2.

Before using the instrument carefully verify the nominal voltage value of the charger; in case of modification do not forget to correct the pertinent label.

The instrument should be used in environments where the temperature does not exceed the specified limits (from -5°C to +50°C) and where the relative humidity is lower than 95%.

Out 1248.3°C Tc

In case of “low” battery condition (voltage lower than 4.6 V) the display will show the appropriate symbol. An empty symbol means that the battery package has enough energy for about 30 minutes operation. A black symbol means that batteries charge is below the minimum acceptable level: operation of the instrument is no longer possible. In this condition the instrument batteries must be recharged.

WARNING

THE INSTRUMENT IS SUPPLIED WITH NI-MHRECHARGEABLE BATTERIES.

DO NOT USE NORMAL ALKALINE BATTERIES.

ALKALINE BATTERIES, WHEN CONNECTED TO A DC VOLTAGE SUPPLY UNDERTAKE AN OVERHEATING PROCESS WITH A RISK OF

EXPLOSION.

19

Image 19
Contents CL526 OMEGAnetSM On-Line Service Internet e-mail Info@omega.com Introductory Note Table of Contents Digital Interface General Performance Specifications Dimensions 120x60x230 mm Weights net 1 Kg Power supplyBattery life Battery voltage32 to +302F ± 0.02% of rdg +0.18F Table of ranges and accuracyGeneral Features Case Physical Description Functional Description Power supply+ 5 V for logic and analog circuits 5 V for analog circuits Input circuit Digital to analog converter MicroprocessorFirmware Digital displayResistance and Rtd measurements Battery charger. Operation from line sourceThermocouples input-output circuit Resistance and Rtd simulationUnpacking Out 1248.3C Tc PRE-OPERATIONAL CheckElectrical Connections Wiring practiceExamples of input /output wiring and connections Thermocouple wiresClass Limit of Error of thermocouple wiresBattery Line Op Power SupplyBattery Charger How to maximize the battery lifeOperation & Applications Power onBattery voltage indication Operating mode set upOut 0.0C TcK OUT mode selectionParameter or sensor selection 1032.2C TcKDecimal point position International Temperature ScaleRj mode Tecnical unitAverage readings Data memory configurationIN-OUT data memories Data memory automatic scanning Data memory manual recallAutomatic simulation cycle Manual step advanceSimulation cycle selection 0mV Time 0h 0m 50sStart 0.0mV End 100.0mVSimulation cycle Rj compensation mode checkProg Mode Linear Mode SquareScale factor program RJ 0.0C extWord psi Word hPa Word mbarFirmware version code Serial number Installation parameter procedureExternal Rj compensation Baud Rate Digital interface data program modeDigital output wiring practice Digital InterfaceCommunication protocol from CL526 to a PC TTL to RS 232 adapterComputer CL526 Data InstructPage Ramp = OHM Computer request for CL526 settingsMode InstrDis/Lin STO 2 #D 127 202 Display Chksum = DATA1 + DATA2 + Data 3 + Data 4 .AND.7F Example a Communication programsExample a data transfer from CL526 to PC Example B PC instructions to CL5263ØØ While LOC 1 = Ø Wend Error Checksum MaintenanceSafety recommendations Faulty operating conditionsStorage Protection fusesIndex WARRANTY/DISCLAIMER Temperature