Omega CL526, Multifunction Indicator-Simulator manual Physical Description

Page 12

3 PHYSICAL DESCRIPTION

The CL526 portable calibrator consists of a rugged and compact case, a mother board with all base functions, a daughter board for the auxiliary functions, a tactile membrane keyboard, an LCD display and a group of four nickel- cadmium rechargeable batteries.

The internal surface of the case is metal coated to improve the characteristics of electrical noise shielding and thermal equalization of all internal circuits.

The battery container is located on the lower part of the case, and is accessible through a cover fastened by a metal screw.

The two halves of the case are joined together by four metal screws located on the back side.

The leather case, with shoulder strap, assures better protection of the instrument against mechanical knocks or scratches.

12

Image 12
Contents CL526 OMEGAnetSM On-Line Service Internet e-mail Info@omega.com Introductory Note Table of Contents Digital Interface General Performance Specifications Power supply Battery lifeBattery voltage Dimensions 120x60x230 mm Weights net 1 Kg Table of ranges and accuracy 32 to +302F ± 0.02% of rdg +0.18FGeneral Features Case Physical Description Power supply Functional Description+ 5 V for logic and analog circuits 5 V for analog circuits Input circuit Microprocessor FirmwareDigital display Digital to analog converterBattery charger. Operation from line source Resistance and Rtd measurementsResistance and Rtd simulation Thermocouples input-output circuitUnpacking PRE-OPERATIONAL Check Out 1248.3C TcWiring practice Electrical ConnectionsThermocouple wires Examples of input /output wiring and connectionsLimit of Error of thermocouple wires ClassPower Supply Battery ChargerHow to maximize the battery life Battery Line OpPower on Battery voltage indicationOperating mode set up Operation & ApplicationsOUT mode selection Parameter or sensor selection1032.2C TcK Out 0.0C TcKInternational Temperature Scale Rj modeTecnical unit Decimal point positionData memory configuration Average readingsIN-OUT data memories Data memory manual recall Data memory automatic scanningManual step advance Automatic simulation cycleSimulation cycle selection Time 0h 0m 50s Start 0.0mVEnd 100.0mV 0mVRj compensation mode check Simulation cycleMode Linear Mode Square Scale factor programRJ 0.0C ext ProgWord mbar Word psi Word hPaInstallation parameter procedure Firmware version code Serial numberExternal Rj compensation Digital interface data program mode Digital output wiring practiceDigital Interface Baud RateTTL to RS 232 adapter Communication protocol from CL526 to a PCComputer CL526 Instruct DataPage Ramp Computer request for CL526 settings = OHMInstr ModeDis/Lin STO 2 #D 127 202 Display Chksum = DATA1 + DATA2 + Data 3 + Data 4 .AND.7F Communication programs Example a data transfer from CL526 to PCExample B PC instructions to CL526 Example a3ØØ While LOC 1 = Ø Wend Maintenance Safety recommendationsFaulty operating conditions Error ChecksumProtection fuses StorageIndex WARRANTY/DISCLAIMER Temperature