Wiring and Connections |
| Section |
Input Devices | The following table shows how to connect various input devices. | |
Device | Circuit diagram |
|
Relay output | Relay |
|
|
| |
|
| IN |
| 5 mA/12 mA | CPM1A |
|
| COM (+) |
NPN open collector | Sensor |
|
|
|
+Sensor power supply
| Output | IN | CPM1A |
| 5 mA/12 mA | ||
|
|
| |
| 0 V | COM (+) |
|
|
|
| |
NPN current output |
| Use the same power supply for | |
|
| the input and sensor. |
Constant | current |
|
|
circuit | + |
|
|
| Output | IN | CPM1A |
| 5 mA/12 mA | ||
| + |
| |
| 0 V | COM (+) |
|
|
|
|
PNP current output
+ | Sensor power | CPM1A |
5 mA/12 mA | supply | |
| IN | |
| ||
Output |
| |
|
|
0 V | COM |
|
|
| |
Voltage output |
|
|
+ | COM (+) | CPM1A |
| ||
|
| |
Output | IN |
|
|
| |
0 V | Sensor power |
|
| supply |
|
50