Omega Multifunction Indicator-Simulator, CL526 manual 3ØØ While LOC 1 = Ø Wend

Page 45

16Ø IDNAME = ASC (INPUT$ (1 , 1)): REM READ RECEIVED IDNAME FROM CL526 17Ø PRINT #1, CHR$ (INSTRUCTION) ;

18Ø WHILE LOC (1) = Ø : WEND

19Ø INSTRUCTION = ASC (INPUT$ (1 , 1)) 2ØØ PRINT #1, CHR$ (DATA1) ;

21Ø WHILE LOC (1) = Ø : WEND

22Ø CHAR = ASC (INPUT$ (1 , 1))

23Ø PRINT #1, CHR$ (DATA2) ;

24Ø WHILE LOC (1) = Ø : WEND

25Ø CHAR = ASC (INPUT$ (1 , 1))

26Ø PRINT #1, CHR$ (DATA3) ;

27Ø WHILE LOC (1) = Ø : WEND

28Ø CHAR = ASC (INPUT$ (1 , 1))

29Ø PRINT #1, CHR$ (DATA4) ;

3ØØ WHILE LOC (1) = Ø : WEND

31Ø CHAR = ASC (INPUT$ (1 , 1))

32Ø PRINT #1, CHR$ (CHKSUM) ;

33Ø WHILE LOC (1) = Ø : WEND

34Ø CHAR = ASC (INPUT$ (1 , 1)) 35Ø PRINT "Trasmitted."

39Ø END

45

Image 45
Contents CL526 OMEGAnetSM On-Line Service Internet e-mail Info@omega.com Introductory Note Table of Contents Digital Interface General Performance Specifications Battery life Power supplyBattery voltage Dimensions 120x60x230 mm Weights net 1 Kg32 to +302F ± 0.02% of rdg +0.18F Table of ranges and accuracyGeneral Features Case Physical Description Power supply Functional Description+ 5 V for logic and analog circuits 5 V for analog circuits Input circuit Firmware MicroprocessorDigital display Digital to analog converterResistance and Rtd measurements Battery charger. Operation from line sourceThermocouples input-output circuit Resistance and Rtd simulationUnpacking Out 1248.3C Tc PRE-OPERATIONAL CheckElectrical Connections Wiring practiceExamples of input /output wiring and connections Thermocouple wiresClass Limit of Error of thermocouple wiresBattery Charger Power SupplyHow to maximize the battery life Battery Line OpBattery voltage indication Power onOperating mode set up Operation & ApplicationsParameter or sensor selection OUT mode selection1032.2C TcK Out 0.0C TcKRj mode International Temperature ScaleTecnical unit Decimal point positionData memory configuration Average readingsIN-OUT data memories Data memory automatic scanning Data memory manual recallManual step advance Automatic simulation cycleSimulation cycle selection Start 0.0mV Time 0h 0m 50sEnd 100.0mV 0mVSimulation cycle Rj compensation mode checkScale factor program Mode Linear Mode SquareRJ 0.0C ext ProgWord psi Word hPa Word mbarInstallation parameter procedure Firmware version code Serial numberExternal Rj compensation Digital output wiring practice Digital interface data program modeDigital Interface Baud RateTTL to RS 232 adapter Communication protocol from CL526 to a PCComputer CL526 Data InstructPage Ramp = OHM Computer request for CL526 settingsMode InstrDis/Lin STO 2 #D 127 202 Display Chksum = DATA1 + DATA2 + Data 3 + Data 4 .AND.7F Example a data transfer from CL526 to PC Communication programsExample B PC instructions to CL526 Example a3ØØ While LOC 1 = Ø Wend Safety recommendations MaintenanceFaulty operating conditions Error ChecksumStorage Protection fusesIndex WARRANTY/DISCLAIMER Temperature