Omnitron Systems Technology 10/100M2 user manual 5 802.3ah Parameters

Page 32

4.3.5802.3ah Parameters

The 802.3ah parameters can be monitored and/or configured in the 802.3ah Control screen.

802.3ah OAM State - The 802.3ah OAM State turns 802.3ah processing on or off for the selected port. When the port is configured as “Disabled” it will not respond to OAMPDUs (OAM Protocol Data Units). They will be dropped by the processor and not acted upon. When the port is configured as “Enabled”, it will respond to and be involved in the Discovery process and other supported 802.3ah OAM functions.

802.3ah OAM Mode - The 802.3ah OAM Mode sets the selected port to “Passive” or “Active” configuration mode. In “Passive” mode the port cannot initiate Discovery, send Variable Requests or initiate Loopback Mode. It can observe and report only the port status of its 802.3ah enabled remote partner. An “Active” port can initiate Discovery, send Variable Requests and initiate loopback mode.

Loopback Mode - The Loopback Mode turns loopback operations “On” or “Off”. When Loopback Mode is set to “Off”, the port of the 802.3ah enabled local device will not initiate Loopback operations. It can respond to loopback commands from its 802.3ah enabled remote partner if set to “Passive” or “Active”. When Loopback Mode is set to “On”, the port of the 802.3ah enabled local device will initiate Loopback operations and set the 802.3ah enabled remote partner into loopback. In this mode, the 802.3ah enabled local device will not respond to any other configuration changes until its port is set to “Off.”

Loopback Mode Timeout (sec) - The Loopback Mode Timeout field controls the length of time that the port will be set to Loopback “On” mode. Loopback can be set between 0 and 300 seconds. The 0 setting disables the timer.

Unidirectional Mode - OAM provides a mechanism to notify the remote link partner when one direction of a link is non-operational and therefore data transmission is disabled. The ability to operate a link in a unidirectional mode for diagnostic purposes supports the maintenance objective of failure detection and notification. The 802.3ah unidirectional link can be enabled on the fiber port. Unidirectional fiber link allows a fiber port to send link fault OAMPDUs when a link fault is detected.

4.3.5.1Local Status Section

The Local Status section displays the status of the Fiber and UTP ports of the 802.3ah enabled local device. The local device is controlled directly by SNMP, Telnet or via the Serial Port and has the ability to communicate with an 802.3ah enabled remote partner.

Discovery State - Indicates the Discovery state (“Complete”, “In Process” or “Incomplete”) of the local ports. If “Complete” is displayed, Discovery has been completed. If “In Process”, Discovery has been initiated but no response from the 802.3ah enabled remote partner has been received by the local device. If “Incomplete”, Discovery has received a response from the 802.3ah enabled remote partner but the Discovery process is not yet completed.

Multiplexer State - Indicates the Multiplexer state (“Discard” or “Forward”) of the local ports. If “Forward” is displayed, the local device is forwarding non-OAMPDU network frames to the lower sublayer. If “Discard”, the local device is discarding non-OAMPDU network frames.

Parser Action - Indicates the Parser Action (“Discard”, “Forward” or “Loopback”) of the local ports. If “Forward” is displayed, the local device is forwarding non-OAMPDU network frames to the higher sublayer. If “Loopback”, the local device is looping back non-OAMPDUs network frames. If “Discard”, the device is discarding non-OAMPDUs network frames.

4.3.5.2Remote Status Section

The Remote Status section displays the status of the ports of the 802.3ah enabled remote partner. These

Page 32

Image 32
Contents Standalone and PLUG-IN Module Table of Contents Overview SA Standalone Plug-InPort Structure Installation Procedure B B B B B B BConfiguring DIP-SWITCHES 1.2 SW2 Fiber Full/Half-Duplex FDX/HDX 1.5 SW5 UTP Full/Half Duplex FDX/HDX These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting the Chassis Number and Name Setting 10/100M2 Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Enabling/Disabling Soft-switch Reload Access the 10/100M2 Remotely Updating the 10/100M2 Firmware via the Serial Console Port Verify Operation Detailed Module Configuration NMM8919N-0 10/100M2 UTP HDX UTP FDX LEDModule Management Mode Port Configuration UTP To change the ingress rate of the UTP port, select option SFP Information A167EC500000 5 802.3ah Parameters Page OUI Port Vlan Page Tagged Vlan BP B PvidVlan Table is Empty Vlan ID VIDUTP BP a BP B Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter 10/100M2 Specifications Cable TypesTroubleshooting Guide Possible CausesUTP Issues Warranty Limitation of Warranty