Omnitron Systems Technology 10/100M2 user manual 1.5 SW5 UTP Full/Half Duplex FDX/HDX

Page 8

100Mbps “100” position (factory default) forces the UTP port to operate at 100Mbps. Setting this DIP-switch to UTP 10Mbps “10” position forces the UTP port to operate at 10Mbps. Adjust the “10/100” DIP-switch to match the speed of the connecting UTP device.

When the UTP “AN/Man” DIP-switch is in the auto-negotiate “AN” position and the UTP 10/100 DIP-switch is in the “100” position, the UTP port auto-negotiates to 100Mbps or 10Mbps. When in the “10” position, the UTP port only operates at 10Mbps. Refer to the table above for a detailed explanation.

3.2.1.5SW5 - UTP Full/Half Duplex “FDX/HDX”

When the UTP “AN/Man” DIP-switch is in the manual “Man” position, the UTP Full/Half-Duplex “FDX/HDX” DIP-switch determines the duplex operation mode of the UTP port. Setting the UTP Full/Half-Duplex DIP-switch to UTP Full-Duplex “FDX” position (factory default) forces the UTP port to operate in Full-Duplex. Setting this DIP-switch to UTP Half-Duplex “HDX” forces the UTP port to operate in Half-Duplex. Adjust the UTP Half/Full-Duplex DIP-switch to match the duplex mode of the connecting UTP device.

When the UTP “AN/Man” DIP-switch is in the auto-negotiate “AN” position, and the UTP Full/Half-Duplex DIP-switch is in the Full-Duplex “FDX” position, the UTP port auto-negotiates to Full or Half-Duplex. When in the Half-Duplex “HDX” position, the UTP port functions only in Half-Duplex for the speed selected. Refer to the table on the previous page for a detailed explanation.

3.2.1.6SW6, SW7, SW8 - Link Modes

These three DIP-switches configure the link mode settings. The following table details possible Link Mode DIP-switch configurations.

 

 

 

 

PI

 

 

 

 

 

SW6

SW7

SW8

Result

 

 

 

 

Left

Left

Left

Link Segment mode (LS)

 

 

 

 

Right

Left

Left

Link Propagate mode (LP)

 

 

 

 

Left

Right

Left

Remote Fault Detection mode plus Link

Segment mode (RFD+LS)

 

 

 

Right

Right

Left

Remote Fault Detection mode plus Link

Propagation mode (RFD+LP)

 

 

 

Left

Left

Right

Symmetrical Fault Detect mode (SFD)

Right

Left

Right

Asymmetrical LP P1 to P2 (ALP P1-P2)

 

 

 

 

Left

Right

Right

Asymmetrical LP P2 to P1 (ALP P2-P1)

 

 

 

 

Right

Right

Right

Asymmetrical RFD+LP P1 to P2

 

 

 

 

 

 

 

 

 

 

SA

 

 

 

 

 

SW6

SW7

SW8

Result

 

 

 

 

Down

Down

Down

Link Segment mode (LS)

 

 

 

 

Up

Down

Down

Link Propagate mode (LP)

 

 

 

 

Down

Up

Down

Remote Fault Detection mode plus Link

 

 

 

Segment mode (RFD+LS)

Up

Up

Down

Remote Fault Detection mode plus Link

 

 

 

Propagation mode (RFD+LP)

Down

Down

Up

Symmetrical Fault Detect mode (SFD)

Up

Down

Up

Asymmetrical LP P1 to P2 (ALP P1-P2)

 

 

 

 

Down

Up

Up

Asymmetrical LP P2 to P1 (ALP P2-P1)

 

 

 

 

Up

Up

Up

Asymmetrical RFD+LP P1 to P2

 

 

 

 

 

 

NOTE: Connecting two converters which are set to any of the RFD modes are illegal and will cause a “deadly embrace” lockup.

NOTE: It is recommended to keep the LS setting (default) until initial configuration is complete.

For detailed information on the operation of the different Link Modes, download the application note “iConverter Link Modes” available on Omnitron’s web page:

http://www.omnitron-systems.com/downloads.php

Page 8

Image 8
Contents Standalone and PLUG-IN Module Table of Contents Overview SA Standalone Plug-InPort Structure Installation Procedure B B B B B B BConfiguring DIP-SWITCHES 1.2 SW2 Fiber Full/Half-Duplex FDX/HDX 1.5 SW5 UTP Full/Half Duplex FDX/HDX These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting the Chassis Number and Name Setting 10/100M2 Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Enabling/Disabling Soft-switch Reload Access the 10/100M2 Remotely Updating the 10/100M2 Firmware via the Serial Console Port Verify Operation Detailed Module Configuration NMM8919N-0 10/100M2 UTP HDX UTP FDX LEDModule Management Mode Port Configuration UTP To change the ingress rate of the UTP port, select option SFP Information A167EC500000 5 802.3ah Parameters Page OUI Port Vlan Page Tagged Vlan BP B PvidVlan Table is Empty Vlan ID VIDUTP BP a BP B Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter 10/100M2 Specifications Cable TypesTroubleshooting Guide Possible CausesUTP Issues Warranty Limitation of Warranty