3.4CONFIGURE THE MODULE VIA COMMAND LINE INTERFACE
PI
SA
To configure, attach the 10/100M2 to a
Serial Connector Pin Outs
Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:” window. Set the PC’s serial port to the following:
Bits Per Second: | 57,600 |
Stop Bits: | 1 |
Data Bits: | 8 |
Parity: | NONE |
Hardware Flow Control: | NONE |
Power the chassis containing the 10/100M2 module and press <ENTER> to bring up a command line prompt on the attached PC.
The module is configured with the following defaults:
IP |
|
IP Address: | 192.168.1.220 |
IP Subnet Mask: | 255.255.255.0 |
Passwords |
|
Serial: | No password assigned |
FTP: | No password assigned |
Telnet: | public |
SNMPv1/v2c Communities
READ: | public |
|
|
WRITE: | public |
|
|
SNMPv3 Parameters |
|
|
|
User 1 name (read only): | guest |
|
|
User 2 name (read/write): | admin |
|
|
User 1 Privacy pwd: | publicguest | User 1 Authen pwd: | publicguest |
User 2 Privacy pwd: | privateadmin | User 2 Authen pwd: | privateadmin |
Page 11