3.4CONFIGURE THE MODULE VIA COMMAND LINE INTERFACE

PI

SA

To configure, attach the 10/100M2 to a DB-9 serial (RS-232) equipped computer with terminal emulation software such as HyperTerminal. The 10/100M2 Serial Console Port (DCE) is a mini DIN-6 female connector which can be changed to a DB-9 connector with the included adapter (Part #8082-0). Attach the ends of a serial cable to the serial port of the PC and the Serial Console Port of the 10/100M2. This is a standard asynchronous serial interface. The pin-outs are illustrated below.

Serial Connector Pin Outs

Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:” window. Set the PC’s serial port to the following:

Bits Per Second:

57,600

Stop Bits:

1

Data Bits:

8

Parity:

NONE

Hardware Flow Control:

NONE

Power the chassis containing the 10/100M2 module and press <ENTER> to bring up a command line prompt on the attached PC.

The module is configured with the following defaults:

IP

 

IP Address:

192.168.1.220

IP Subnet Mask:

255.255.255.0

Passwords

 

Serial:

No password assigned

FTP:

No password assigned

Telnet:

public

SNMPv1/v2c Communities

READ:

public

 

 

WRITE:

public

 

 

SNMPv3 Parameters

 

 

 

User 1 name (read only):

guest

 

 

User 2 name (read/write):

admin

 

 

User 1 Privacy pwd:

publicguest

User 1 Authen pwd:

publicguest

User 2 Privacy pwd:

privateadmin

User 2 Authen pwd:

privateadmin

Page 11

Image 11
Contents Standalone and PLUG-IN Module Table of Contents SA Standalone Plug-In OverviewPort Structure B B B B B B B Installation ProcedureConfiguring DIP-SWITCHES 1.2 SW2 Fiber Full/Half-Duplex FDX/HDX 1.5 SW5 UTP Full/Half Duplex FDX/HDX These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting the Chassis Number and Name Setting 10/100M2 Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Enabling/Disabling Soft-switch Reload Access the 10/100M2 Remotely Updating the 10/100M2 Firmware via the Serial Console Port Verify Operation NMM Detailed Module Configuration8919N-0 10/100M2 LED UTP HDX UTP FDXModule Management Mode Port Configuration UTP To change the ingress rate of the UTP port, select option SFP Information A167EC500000 5 802.3ah Parameters Page OUI Port Vlan Page Tagged Vlan Pvid BP BVlan Table is Empty Vlan ID VIDUTP BP a BP B Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter Cable Types 10/100M2 SpecificationsPossible Causes Troubleshooting GuideUTP Issues Limitation of Warranty Warranty