Omnitron Systems Technology 10/100M2 user manual Setting Snmp Preferences

Page 16

PI

SA

IP and Control Preferences Screen

iConverter, Serial Agent

1:

Set IP

 

192.168.1.220

2:

Set Subnet Mask

255.255.255.0

3:

Set Gateway

192.168.1.1

4:

Chassis Number

1

5:

Chassis Name (also sysName)

10/100M2

6:

Enable/Disable TELNET

Enabled

7:

Enable/Disable FTP

Disabled

8:

Enable/Disable Soft Switch Reload

Disabled

9:

TELNET Password

*****

10: FTP

Password

 

11: Serial Password

 

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.

3.4.2Setting SNMP Preferences

To set the SNMP Preferences for the 10/100M2 module, select 4 from the Management Options screen, press <ENTER> to enter the SNMP Preferences screen.

PI

SA

Management Options

iConverter, Serial Agent

Network Management

1:Chassis and Module Management

2:Set Module Identifier

Management Module Preferences

3:IP and Control Preferences

4:SNMP Preferences

5:Abandon Preference Changes

6:Save Preference Changes

7:Restore to Factory Defaults

8:Restart Management Module

9:Other Networking Features

Management Module Maintenance

10:Firmware Update

11:Set Date/Time

IP Address

= 192.168.1.220

Chassis Number = 1

Enter Choice, (H)elp, E(x)it > 4

Page 16

Image 16
Contents Standalone and PLUG-IN Module Table of Contents Overview SA Standalone Plug-InPort Structure Installation Procedure B B B B B B BConfiguring DIP-SWITCHES 1.2 SW2 Fiber Full/Half-Duplex FDX/HDX 1.5 SW5 UTP Full/Half Duplex FDX/HDX These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting the Chassis Number and Name Setting 10/100M2 Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Enabling/Disabling Soft-switch Reload Access the 10/100M2 Remotely Updating the 10/100M2 Firmware via the Serial Console Port Verify Operation Detailed Module Configuration NMM8919N-0 10/100M2 UTP HDX UTP FDX LEDModule Management Mode Port Configuration UTP To change the ingress rate of the UTP port, select option SFP Information A167EC500000 5 802.3ah Parameters Page OUI Port Vlan Page Tagged Vlan BP B PvidUTP BP a BP B Vlan ID VIDVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter 10/100M2 Specifications Cable TypesTroubleshooting Guide Possible CausesUTP Issues Warranty Limitation of Warranty