3.4.3Enabling/Disabling Soft-switch Reload
The Soft-switch Reload function controls the configurations of the 10/100M2 and other iConverter modules managed by the 10/100M2 following a power up.
When the Soft-switch Reload is disabled, the configurations of the 10/100M2 and the other managed modules (non-management modules) are determined by their hardware DIP-switch settings following a return of power.
When the Soft-switch Reload is enabled, the configurations of the 10/100M2 and the other managed modules are determined by the previous software settings stored in the FLASH memory of the 10/100M2 following a return of power. Each of the hardware DIP-switch settings on the module are ignored until a change is made to the DIP-switch, then the hardware settings will take effect.
To set the Soft-switch Reload function, select 8 at the IP and Control Preferences screen, press <ENTER> and then follow the screen prompts to change the setting.
IP and Control Preferences Screen | iConverter, Serial Agent |
1: | Set IP | | 192.168.1.220 |
2: | Set Subnet Mask | 255.255.255.0 |
3: | Set Gateway | 192.168.1.1 |
4: | Chassis Number | 1 |
5: | Chassis Name (also sysName) | 10/100M2 |
6: | Enable/Disable TELNET | Enabled |
7: | Enable/Disable FTP | Disabled |
8: | Enable/Disable Soft Switch Reload | Disabled |
9: | TELNET Password | ***** |
10: FTP | Password | |
11: Serial Password | |
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.