Omnitron Systems Technology 10/100M2 user manual UTP Issues

Page 46

6.1.3UTP Issues

Problem:

The UTP link LED does not illuminate after installation is complete.

Possible Causes:

A. Confirm that the UTP cable is connected properly to the iConverter 10/100M2 and the attached UTP device. Once a connection has been established between the iConverter and its link partner (switch or workstation), the UTP “10/100” LED should illuminate. If the LED does not illuminate, check the Link Mode configuration. A link mode other than Link Segment may cause the UTP “10/100” LED not to turn ON.

B. Verify the iConverter 10/100M2 UTP port is configured with the proper settings based on the attached device (AN or MAN, 10 or 100, HD or FD).

C. Verify the distance between the iConverter and the link partner is within 100 meters.

D. Confirm that the UTP cable pin-out is correct (EIA/TIA-568-A). The module has auto-crossover capability, so it will accept either a straight-through or crossover cable.

NOTE: If corrective actions do not resolve your situation, please contact Omnitron Systems Technical Support.

Page 46

Image 46
Contents Standalone and PLUG-IN Module Table of Contents Overview SA Standalone Plug-InPort Structure Installation Procedure B B B B B B BConfiguring DIP-SWITCHES 1.2 SW2 Fiber Full/Half-Duplex FDX/HDX 1.5 SW5 UTP Full/Half Duplex FDX/HDX These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting the Chassis Number and Name Setting 10/100M2 Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Enabling/Disabling Soft-switch Reload Access the 10/100M2 Remotely Updating the 10/100M2 Firmware via the Serial Console Port Verify Operation Detailed Module Configuration NMM8919N-0 10/100M2 UTP HDX UTP FDX LEDModule Management Mode Port Configuration UTP To change the ingress rate of the UTP port, select option SFP Information A167EC500000 5 802.3ah Parameters Page OUI Port Vlan Page Tagged Vlan BP B PvidUTP BP a BP B Vlan ID VIDVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter 10/100M2 Specifications Cable TypesTroubleshooting Guide Possible CausesUTP Issues Warranty Limitation of Warranty