4.3.9VLAN Membership Table

The VLAN Membership Table lists the permitted VLAN ID (VID) for each egress port on the module. Only packets that are assigned a VID value that matches one of the egress port’s VID memberships are allowed to egress through the port.

When the Ingress Security is set to High for a specific port, the membership table is used to list the VIDs of the packets that are allowed to ingress that port.

VLAN Membership is accessed by selecting option 3 from the Port configuration screen. The VLAN Membership screen will be displayed.

PI

VLAN Membership - iConverter 10/100M2

 

iConverter, Serial Agent

Identifier -

 

 

 

 

 

 

Chassis Number = 1

Slot Number = 1

Model Number = 8919N-0

 

 

VLAN ID (VID)

Fiber

UTP

BP A

BP B

Mngmnt

 

VLAN TABLE IS EMPTY

 

 

 

 

 

 

Add new entry (a), Delete entry (d), Edit entry (e), Clear table (c)

Enter Choice, Previous Screen(0), (H)elp, E(x)it >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SA

 

 

 

 

 

 

 

 

 

 

VLAN Membership - iConverter 10/100M2

 

iConverter, Serial Agent

Identifier -

 

 

 

 

 

 

Chassis Number = 1

Slot Number = 1

Model Number = 8919N-0

 

 

VLAN ID (VID)

Fiber

UTP

Mngmnt

 

 

 

VLAN TABLE IS EMPTY

 

 

 

 

 

Add new entry (a), Delete entry (d), Edit entry (e), Clear table (c)

Enter Choice, Previous Screen(0), (H)elp, E(x)it >

Page 39

Image 39
Contents Standalone and PLUG-IN Module Table of Contents SA Standalone Plug-In OverviewPort Structure B B B B B B B Installation ProcedureConfiguring DIP-SWITCHES 1.2 SW2 Fiber Full/Half-Duplex FDX/HDX 1.5 SW5 UTP Full/Half Duplex FDX/HDX These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting the Chassis Number and Name Setting 10/100M2 Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Enabling/Disabling Soft-switch Reload Access the 10/100M2 Remotely Updating the 10/100M2 Firmware via the Serial Console Port Verify Operation NMM Detailed Module Configuration8919N-0 10/100M2 LED UTP HDX UTP FDXModule Management Mode Port Configuration UTP To change the ingress rate of the UTP port, select option SFP Information A167EC500000 5 802.3ah Parameters Page OUI Port Vlan Page Tagged Vlan Pvid BP BVlan ID VID UTP BP a BP BVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter Cable Types 10/100M2 SpecificationsPossible Causes Troubleshooting GuideUTP Issues Limitation of Warranty Warranty