MRV Communications TS5000/ETH/V*, TS5000/XYZ/V**, TS5000/4U1/V*) installation manual Appendixb

Page 69

M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

APPENDIXB

Digital Readout vs. Distance

These tables are only intended to give you an idea of what digital readout you could expect according to the distance to link.

D= Distance [m]

R= Reading (Digital readout)

TS5000/G and

 

D

 

400

500

600

700

800

900

1000

1100

1200

1400

1500

TS5000/G-F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

1100

950

820

700

780

700

620

560

500

440

380

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

1600

1800

2000

2200

2400

2600

2800

3000

3500

4000

 

 

 

R

 

360

280

240

220

180

160

135

125

95

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TS5000/155 and TS5000/155-F

Rev 3.0 and less

D

600

800

1000

1200

1400

1600

1800

2000

 

 

 

 

 

 

 

 

 

R

1050

1000

940

880

840

830

810

800

 

 

 

 

 

 

 

 

 

 

 

 

D

 

2200

 

2400

 

2600

 

2800

 

3000

 

3500

 

4000

 

5000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

790

 

780

 

760

 

750

 

740

 

720

 

680

 

580

 

 

 

 

 

 

 

TS5000/155 and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

400

 

500

 

600

 

700

 

800

 

900

 

1000

 

1100

 

1200

1400

1500

1600

1800

2000

TS5000/155-F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

1270

 

1250

 

1070

 

1020

 

990

 

970

 

950

 

940

 

930

920

910

890

840

780

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

2200

 

2400

 

2600

 

2800

 

3000

 

3500

 

4000

 

4300

 

4600

5000

5300

5600

6000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

730

 

680

 

650

 

630

 

570

 

530

 

490

 

465

 

450

440

420

410

390

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TS5000/ETH and

 

 

D

 

400

 

500

 

600

 

700

 

800

 

900

 

1000

 

1100

 

1200

1400

1500

1600

1800

2000

TS5000/4U1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

1220

 

1220

 

1150

 

1040

 

990

 

920

 

870

 

850

 

800

720

710

705

700

670

(4E1 or 4T1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

2200

 

2400

 

2600

 

2800

 

3000

 

3500

 

4000

 

4300

 

4600

5000

5300

5600

6000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

630

 

590

 

570

 

540

 

510

 

470

 

430

 

410

 

390

360

350

330

320

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Actual reading may be greater or up to 15% lower.

Even when there is no transmission from the opposite side, the digital readout of

TS5000 can show a certain reading: up to 5-6 in laboratory and up to 20 outside.

58

Image 69
Contents InstallationManual Installation Manual Table of Contents Page TereScope Bench Test Procedure Product specificationsPower Supply Replacement Digital Readout vs. DistanceStandards Compliance StandardsFCC Notice CE MarkOther Standards MRV Laser Safety CertificationDisclaimer TrademarksAboutthisInstallationManual Before Installing SafetyRequirementsWhen Installing Line Power Power CordServicing Introduction Carefully Read the Entire Manual Before InstallingTheProduct ModelsModels Part Number Description TS5000/M3C/V1S Using the Part Number for OrderingGeneral Description FrontBack TS5000/G Standard Model w/o Fusion and with one power supply Back Panel Description Selectors Indicators For more details please see pages 15 TS5000/155 w/o Fusion and with one power supply Power Power Supply Figures 1.5and Indicators TS5000/155-FStandard Model including Fusion option RF Transceiver Fusion Operation ModeIR = 100 Mbps or 1.25Gbps RF = 2-10 Mbps Or 100Mbps7b TS & Fusion FusionTS5000/ETH Model Back Panel TS5000/ETH Ethernet SystemSelectors DIP TS5000-4U1 Model Back Panel TS5000/4U1 4E1 or 4T1 SystemTo D Dip switch settingLoop and Remote Loop Operation Mode When turning off the Master, the Slave exits Loop stateHeating Management Monitoring and Management optionsDry contact RSMTypical Connection Fiber ConnectionCopper Connection Line of Sight SiteSurveyOrientation Location & RangePrefer Avoid Pay attention to Acceptable Mounting Unacceptable Mounting Mounting Environment & StabilityWall Mounting using JMP and JMB Transmitting through a Window 10 Extended Wall Mounting using JMP and MO62CPower Data/Signal CablingInfrastructure Handle the Fibers Very Carefully Setup Testing equipmentBenchTest CompatibilityTS5000/155&TS5000/155-F TS5000/4U1 Dip-switch SetupBench test Test ConfigurationsIR link Received power IndicatorsOptical Power Display and ResultsAIR RX Snmp Management Setting and Operation 1001000 Installation AccessoriesDescription Do not touch this screw K Alignment Knobs Installer Tool Kit JITK-8Mounting Accessories11b Locking the screws between TS and alignment device Do not open Screws GMounting on the floor Particular Figure Cases/TechniquesPowering on the TereScope AimingProcedure− Coarse Alignment − Fine Alignment Transceiver AlignmentSwing Base Screws D & L are closedClosed J-R-3Beam cross section at the shot distance Procedure Before Closing the Rear Door An example of an installation form is shown in Appendix HInstallationCompletion Visual InspectionClosing the rear door 13 Mounted TS5000 Left View Periodic Visits MaintenanceTS5000/G TS5000/155 and TS5000/155-F TS5000/ETH TS5000/4U1 4E1 or 4T1 Appendixb Packing box contains AppendixcAppendixd Tool Case Where to usePoints to Remember IntroductionInterference Bench Test for TS700 and TS800 series with JAH-L Figure E.2b Bench Test setup drawing for 10 TS modelFigure E.5 Bench test with TereScopes elevated Page Wind Force = 0.79 x Wind Speed2 x Area of Surface TS Device Momentary ExtendedFSO Chaining AppendixGUse the indoor switch in building C for the chaining SwitchFSO products & Chaining Product series No of chained links Client / Dealer details Application detailsSketch of the area Site survey Installation System failure Appendixi TS5000/155 and TS4000/155 enhancements Appendixj

TS5000/ETH/V*, TS5000/XYZ/V**, TS5000/XXX (TS5000G/XYZ/V**, TS5000/4U1/V*) specifications

MRV Communications has established a strong reputation in the networking industry, known for delivering innovative solutions that enhance the performance and reliability of communication systems. One of their standout product lines is the TS5000 series, which includes models such as TS5000/4U1/V*, TS5000/XXX, TS5000G/XYZ/V**, TS5000/XYZ/V**, and TS5000/ETH/V*. These devices are engineered to meet the growing demands of modern networks, providing a range of features that cater to various connectivity needs.

The TS5000 series is designed with versatility in mind, accommodating multiple deployment scenarios in both enterprise and service provider environments. One of the key features of the TS5000 models is their comprehensive support for multi-service operations. This means they can seamlessly handle different types of traffic including voice, video, and data, making them ideal for organizations that require robust communication solutions.

Incorporating state-of-the-art technologies, the TS5000 series supports various networking protocols and standards. This interoperability ensures compatibility with a wide array of existing network setups, allowing for easier integration and reduced overhead costs. The series utilizes advanced Ethernet technologies that enhance bandwidth efficiency and support high-speed data transfers.

Reliability is another hallmark of the TS5000 series. These devices are built with redundancy in mind, featuring hot-swappable components and failover capabilities that minimize downtime. This is critical for organizations that cannot afford interruptions in service, such as those in the finance or healthcare sectors.

Security is also a priority in the design of the TS5000 series. With built-in encryption and secure access controls, these devices help organizations protect sensitive data from cyber threats. The management interface is designed for ease of use, allowing IT teams to monitor and configure the system effortlessly.

Another notable characteristic of the TS5000 series is its scalability. Organizations can start with a basic configuration and expand their network capabilities as their needs grow. This flexibility makes the TS5000 an ideal choice for businesses aiming for future growth.

In summary, the MRV Communications TS5000 series represents a comprehensive solution for today's networking challenges. With its focus on multi-service support, advanced technology, reliability, security, and scalability, the TS5000 models are well-equipped to serve the demands of diverse environments, making them a valuable addition to any network infrastructure.