MRV Communications TS5000/XYZ/V**, TS5000/ETH/V*, TS5000/4U1/V*) TS5000/4U1 4E1 or 4T1

Page 68

M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

TS5000/4U1 (4E1 or 4T1)

Part Number

Model

Standard P.N

Application / Data Protocol

Performance

Transmitter

Receiver

Interface

Power Supply

Range @ 3dB/km @ 5dB/km @ 10dB/km @ 17dB/km @ 30dB/km

Minimum Range

Bit Error Rate

MTBF

Light source

Wavelength

Total Output power

Beam divergence

Detector

Field of view

Sensitivity

Type

Connectors

Cable

Cable Losses

TS5000/4E1/V* or TS5000/4T1/V*

TS5000/4E1 or TS5000/4T1

TS5000/4E1/VS

4E1: 4x2.048Mbps or 4T1: 4x1.55Mbps

G.703/G.704

6700 m

5000 m

3200 m

2170 m

1400 m

400 m

Less than 1E-9 (unfaded)

10years 3 x Lasers

830-860 nm

85mW

2mrad

APD

2mrad

-55 dBm

Electrical: E1: 75 Ohm or 120 Ohm, T1: 100 Ohm

Universal Connector

STP or Coax

Supports Short and Long haul trunks

Factory set: 100-240 VAC @ 50/60 Hz or 35-60 VDC (V3 Version)

(30 W)

Environmental Information

Mechanical Design

Diagnostics Indicators and Selectors

Operating Temp.

Storage Temp.

Humidity

Housing

Eye safety Class

Dimensions [mm]

Weight Unit Accessories

Modularity

Indicators

Selectors

Dry Contact

Management

-30 °C to +50 °C

-50 °C to +70 °C

95% non-condensing

Weatherproof – IP 66

1M

790 X 390 X 556 (AD-5000: 250x353x432)

14kg 21.5kg

Modular Power supply

Airlink: Flag, Sync. E1 Ports: LED per port.

Receive Signal Strength (Digital Display),

Lasers status (3 LEDs)

Termination, Electrical receive sensitivity, Line incoding, Local Loopback, Remote Loopback, IP address setting

6 Dry Contact outputs: 4 for interface ports

1for air-link flag

1 for air-link sync

SNMP Protocol – Built-in

57

Image 68
Contents InstallationManual Installation Manual Table of Contents Page Product specifications TereScope Bench Test ProcedurePower Supply Replacement Digital Readout vs. DistanceStandards Standards ComplianceFCC Notice CE MarkMRV Laser Safety Certification Other StandardsDisclaimer TrademarksAboutthisInstallationManual SafetyRequirements Before InstallingWhen Installing Line Power Power CordServicing Carefully Read the Entire Manual Before Installing IntroductionModels Part Number Description TheProductModels Using the Part Number for Ordering TS5000/M3C/V1SFront General DescriptionBack TS5000/G Standard Model w/o Fusion and with one power supply Back Panel Description Selectors Indicators For more details please see pages 15 TS5000/155 w/o Fusion and with one power supply Power Power Supply Figures 1.5and Indicators TS5000/155-FStandard Model including Fusion option Fusion Operation Mode RF TransceiverIR = 100 Mbps or 1.25Gbps RF = 2-10 Mbps Or 100MbpsFusion 7b TS & FusionTS5000/ETH Ethernet System TS5000/ETH Model Back PanelSelectors DIP TS5000/4U1 4E1 or 4T1 System TS5000-4U1 Model Back PanelDip switch setting To DHeating Loop and Remote Loop Operation ModeWhen turning off the Master, the Slave exits Loop state Monitoring and Management options ManagementDry contact RSMCopper Connection Typical ConnectionFiber Connection SiteSurvey Line of SightOrientation Location & RangePrefer Avoid Pay attention to Acceptable Mounting Mounting Environment & Stability Unacceptable MountingWall Mounting using JMP and JMB 10 Extended Wall Mounting using JMP and MO62C Transmitting through a WindowInfrastructure PowerData/Signal Cabling Handle the Fibers Very Carefully Testing equipment SetupBenchTest CompatibilityTS5000/155&TS5000/155-F Dip-switch Setup TS5000/4U1Test Configurations Bench testIR link Indicators Received powerOptical Power Display and ResultsAIR RX 1000 Snmp Management Setting and Operation100 Description InstallationAccessories Do not touch this screw K Installer Tool Kit JITK-8 Alignment KnobsAccessories MountingDo not open Screws G 11b Locking the screws between TS and alignment deviceParticular Figure Cases/Techniques Mounting on the floorAimingProcedure Powering on the TereScopeTransceiver Alignment − Coarse Alignment − Fine AlignmentSwing Base Screws D & L are closedBeam cross section at the shot distance ClosedJ-R-3 Procedure An example of an installation form is shown in Appendix H Before Closing the Rear DoorClosing the rear door InstallationCompletionVisual Inspection 13 Mounted TS5000 Left View Maintenance Periodic VisitsTS5000/G TS5000/155 and TS5000/155-F TS5000/ETH TS5000/4U1 4E1 or 4T1 Appendixb Appendixc Packing box containsAppendixd Where to use Tool CaseIntroduction Points to RememberInterference Figure E.2b Bench Test setup drawing for 10 TS model Bench Test for TS700 and TS800 series with JAH-LFigure E.5 Bench test with TereScopes elevated Page TS Device Momentary Extended Wind Force = 0.79 x Wind Speed2 x Area of SurfaceAppendixG FSO ChainingSwitch Use the indoor switch in building C for the chainingFSO products & Chaining Product series No of chained links Sketch of the area Client / Dealer detailsApplication details Site survey Installation System failure Appendixi Appendixj TS5000/155 and TS4000/155 enhancements

TS5000/ETH/V*, TS5000/XYZ/V**, TS5000/XXX (TS5000G/XYZ/V**, TS5000/4U1/V*) specifications

MRV Communications has established a strong reputation in the networking industry, known for delivering innovative solutions that enhance the performance and reliability of communication systems. One of their standout product lines is the TS5000 series, which includes models such as TS5000/4U1/V*, TS5000/XXX, TS5000G/XYZ/V**, TS5000/XYZ/V**, and TS5000/ETH/V*. These devices are engineered to meet the growing demands of modern networks, providing a range of features that cater to various connectivity needs.

The TS5000 series is designed with versatility in mind, accommodating multiple deployment scenarios in both enterprise and service provider environments. One of the key features of the TS5000 models is their comprehensive support for multi-service operations. This means they can seamlessly handle different types of traffic including voice, video, and data, making them ideal for organizations that require robust communication solutions.

Incorporating state-of-the-art technologies, the TS5000 series supports various networking protocols and standards. This interoperability ensures compatibility with a wide array of existing network setups, allowing for easier integration and reduced overhead costs. The series utilizes advanced Ethernet technologies that enhance bandwidth efficiency and support high-speed data transfers.

Reliability is another hallmark of the TS5000 series. These devices are built with redundancy in mind, featuring hot-swappable components and failover capabilities that minimize downtime. This is critical for organizations that cannot afford interruptions in service, such as those in the finance or healthcare sectors.

Security is also a priority in the design of the TS5000 series. With built-in encryption and secure access controls, these devices help organizations protect sensitive data from cyber threats. The management interface is designed for ease of use, allowing IT teams to monitor and configure the system effortlessly.

Another notable characteristic of the TS5000 series is its scalability. Organizations can start with a basic configuration and expand their network capabilities as their needs grow. This flexibility makes the TS5000 an ideal choice for businesses aiming for future growth.

In summary, the MRV Communications TS5000 series represents a comprehensive solution for today's networking challenges. With its focus on multi-service support, advanced technology, reliability, security, and scalability, the TS5000 models are well-equipped to serve the demands of diverse environments, making them a valuable addition to any network infrastructure.