SafetyRequirements

All requirements stipulated in the safety laws of the country of installation must be abided by when installing the TereScopes.

Caution!

In addition, ensure that the requirements noted in this chapter are met in order to reduce risk of electrical shock and fire and to maintain proper installation.

Before Installing

Power: Ensure that all power to the TereScope is cut off. Specifically, disconnect all TereScope power cords from the power line (mains). Inspection: Ensure by inspection that no part is damaged.

Before Powering On

Line Power:

Power Cord:

Figure A: 3 terminal cord forks

Ensure that the power from the line (mains) is as specified on the TereScope.

The power cord of The TereScope must have the following specifications:

Flexible 3-conductor power cord approved by the cognizant safety organization of the country. The power cord must be Type HAR (harmonized), with individual conductor wire having cross-sectional area 0.75 sq. mm. min. The power cord terminations should be a suitably rated earthing-type plug at one end and 3 terminal cord forks for M3 screws (1 for each wire) at the other end. Both of the power cord terminations must carry the certification label of the cognizant safety organization of the country.

When Installing

Ensure, by visual inspection, that no part of the TereScope is damaged.

Avoid eye contact with the laser beam at all times.

Ensure that the system is installed in accordance with ANSI Z136.1 control measures (engineering, administrative, and procedural controls).

Ensure that the system is installed in accordance with applicable building and installations codes.

Install the TereScope in a restricted location as defined in this manual since it is a Class 1M FSOCS transmitter and receiver. A restricted location is a location where access to the transmission equipment and exposed beam is restricted and not accessible to the general public or

iv

Image 9
Contents InstallationManual Installation Manual Table of Contents Page TereScope Bench Test Procedure Product specificationsPower Supply Replacement Digital Readout vs. DistanceStandards Compliance StandardsFCC Notice CE MarkOther Standards MRV Laser Safety CertificationDisclaimer TrademarksAboutthisInstallationManual Before Installing SafetyRequirementsWhen Installing Line Power Power CordServicing Introduction Carefully Read the Entire Manual Before InstallingTheProduct ModelsModels Part Number Description TS5000/M3C/V1S Using the Part Number for OrderingGeneral Description FrontBack TS5000/G Standard Model w/o Fusion and with one power supply Back Panel Description Selectors Indicators For more details please see pages 15 TS5000/155 w/o Fusion and with one power supply Power Power Supply Figures 1.5and Indicators TS5000/155-FStandard Model including Fusion option RF Transceiver Fusion Operation ModeIR = 100 Mbps or 1.25Gbps RF = 2-10 Mbps Or 100Mbps7b TS & Fusion FusionTS5000/ETH Model Back Panel TS5000/ETH Ethernet SystemSelectors DIP TS5000-4U1 Model Back Panel TS5000/4U1 4E1 or 4T1 SystemTo D Dip switch settingLoop and Remote Loop Operation Mode When turning off the Master, the Slave exits Loop stateHeating Management Monitoring and Management optionsDry contact RSMTypical Connection Fiber ConnectionCopper Connection Line of Sight SiteSurveyOrientation Location & RangePrefer Avoid Pay attention to Acceptable Mounting Unacceptable Mounting Mounting Environment & StabilityWall Mounting using JMP and JMB Transmitting through a Window 10 Extended Wall Mounting using JMP and MO62CPower Data/Signal CablingInfrastructure Handle the Fibers Very Carefully Setup Testing equipmentBenchTest CompatibilityTS5000/155&TS5000/155-F TS5000/4U1 Dip-switch SetupBench test Test ConfigurationsIR link Received power IndicatorsOptical Power Display and ResultsAIR RX Snmp Management Setting and Operation 1001000 Installation AccessoriesDescription Do not touch this screw K Alignment Knobs Installer Tool Kit JITK-8Mounting Accessories11b Locking the screws between TS and alignment device Do not open Screws GMounting on the floor Particular Figure Cases/TechniquesPowering on the TereScope AimingProcedure− Coarse Alignment − Fine Alignment Transceiver AlignmentSwing Base Screws D & L are closedClosed J-R-3Beam cross section at the shot distance Procedure Before Closing the Rear Door An example of an installation form is shown in Appendix HInstallationCompletion Visual InspectionClosing the rear door 13 Mounted TS5000 Left View Periodic Visits MaintenanceTS5000/G TS5000/155 and TS5000/155-F TS5000/ETH TS5000/4U1 4E1 or 4T1 Appendixb Packing box contains AppendixcAppendixd Tool Case Where to usePoints to Remember IntroductionInterference Bench Test for TS700 and TS800 series with JAH-L Figure E.2b Bench Test setup drawing for 10 TS modelFigure E.5 Bench test with TereScopes elevated Page Wind Force = 0.79 x Wind Speed2 x Area of Surface TS Device Momentary ExtendedFSO Chaining AppendixGUse the indoor switch in building C for the chaining SwitchFSO products & Chaining Product series No of chained links Client / Dealer details Application detailsSketch of the area Site survey Installation System failure Appendixi TS5000/155 and TS4000/155 enhancements Appendixj

TS5000/ETH/V*, TS5000/XYZ/V**, TS5000/XXX (TS5000G/XYZ/V**, TS5000/4U1/V*) specifications

MRV Communications has established a strong reputation in the networking industry, known for delivering innovative solutions that enhance the performance and reliability of communication systems. One of their standout product lines is the TS5000 series, which includes models such as TS5000/4U1/V*, TS5000/XXX, TS5000G/XYZ/V**, TS5000/XYZ/V**, and TS5000/ETH/V*. These devices are engineered to meet the growing demands of modern networks, providing a range of features that cater to various connectivity needs.

The TS5000 series is designed with versatility in mind, accommodating multiple deployment scenarios in both enterprise and service provider environments. One of the key features of the TS5000 models is their comprehensive support for multi-service operations. This means they can seamlessly handle different types of traffic including voice, video, and data, making them ideal for organizations that require robust communication solutions.

Incorporating state-of-the-art technologies, the TS5000 series supports various networking protocols and standards. This interoperability ensures compatibility with a wide array of existing network setups, allowing for easier integration and reduced overhead costs. The series utilizes advanced Ethernet technologies that enhance bandwidth efficiency and support high-speed data transfers.

Reliability is another hallmark of the TS5000 series. These devices are built with redundancy in mind, featuring hot-swappable components and failover capabilities that minimize downtime. This is critical for organizations that cannot afford interruptions in service, such as those in the finance or healthcare sectors.

Security is also a priority in the design of the TS5000 series. With built-in encryption and secure access controls, these devices help organizations protect sensitive data from cyber threats. The management interface is designed for ease of use, allowing IT teams to monitor and configure the system effortlessly.

Another notable characteristic of the TS5000 series is its scalability. Organizations can start with a basic configuration and expand their network capabilities as their needs grow. This flexibility makes the TS5000 an ideal choice for businesses aiming for future growth.

In summary, the MRV Communications TS5000 series represents a comprehensive solution for today's networking challenges. With its focus on multi-service support, advanced technology, reliability, security, and scalability, the TS5000 models are well-equipped to serve the demands of diverse environments, making them a valuable addition to any network infrastructure.