Multi-Tech Systems MT5600BA-V92 manual Revision Date Description

Page 2

Copyright and Technical Support

MultiModem II User Guide

MT5600BA–V92

PN S000408A

Copyright

All rights reserved. This publication may not be reproduced.

Copyright © 2006 by Multi-Tech Systems, Inc.

Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.

Record of Revisions

Revision Date Description

A08/16/06 Initial release.

Trademarks

MultiModem, Multi-Tech, and the Multi-Tech logo are trademarks or registered trademarks of Multi-Tech Systems, Inc.

Adobe and Acrobat are trademarks of Adobe Systems Incorporated. Microsoft, Windows, Windows 2000+ and XP are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. All other brand and product names mentioned in this publication are trademarks or registered trademarks of their respective companies.

Patents

This device is covered by one or more of the following patents: 6,031,867; 6,012,113; 6,009,082; 5,905,794; 5,864,560; 5,815,567; 5,815,503; 5,812,534; 5,809,068; 5,790,532; 5,764,628; 5,764,627; 5,754,589; 5,724,356; 5,673,268; 5,673,257; 5,644,594; 5,628,030; 5,619,508; 5,617,423; 5,600,649; 5,592,586; 5,577,041; 5,574,725; 5,559,793; 5,546,448; 5,546,395; 5,535,204; 5,500,859; 5,471,470; 5,463,616; 5,453,986; 5,452,289; 5,450,425; D353,598; 5,355,365; 5,309,562; 5,301,274. Other patents pending.

World Headquarters

Multi-Tech Systems, Inc.

2205 Woodale Drive

Mounds View, Minnesota 55112 Phone: 763-785-3500 or 800-328-9717 Fax: 763-785-9874

Technical Support

 

 

 

Country

By Email

By Phone

France:

support@multitech.fr

+(33) 1-64 61 09 81

India:

support@multitechindia.com

+91 (124)

2340780

Europe, Asia, Africa:

support@multitech.co.uk

+(44) 118

959 7774

U.S., Canada, all others:

support@multitech.com

(800) 972-2439 or

 

 

763-717-5863

Internet Address: http://www.multitech.com

Multi-Tech Systems, Inc. MT5600BA-V92 User Guide

2

Image 2
Contents MultiModem Revision Date Description Table of Contents Product Description Product Description FeaturesFeatures Safety Warnings About AT CommandsTechnical Specifications Modem CompatibilityOperating Temperature Connect the Modem to Your System InstallationTwo-Wire or Four-Wire Leased Line Connection Connect the Modem to Your PCPower-On Test Install the Modem DriverConnect the Modem to the AC Power Outlet Installing the Modem DriverSetting Your Country or Region Code Using the LCD Panel Country or Region CodesUsing the Global Wizard Using AT CommandsInstall PhoneTools LED Indicators Using the Front PanelModem Configuration Liquid Crystal Display LCD Option SelectionStatus Trunk Basic Options Trunk Basic Options Trunk Advanced Options Trunk Advanced Options Trunk Remote Configuration Options Trunk Diagnostic Options TrunkPhone Number Memory Options Trunk Caller ID Options TrunkSetting Country/Region Codes Trunk Caller ID Region SelectFunctionality of Menu Options StatusBasic Options Online OptionsCommand Mode Options Advanced Options RS232 OptionsCallback Security Phone Number Memory Options Remote Configuration OptionsDiagnostic Options Caller ID Options Region Select OptionsTwo-Wire / Four-Wire Setup Leased Line OperationFour-Wire Setup Dial BackupDial Backup and Leased Line Restore Setup Setup Changing the Remote Configuration Password Remote ConfigurationBasic Procedure Changing the Remote Escape Character Turning Callback Security On and Off Setup ProceduresCallback Security Assigning Callback Passwords Front Panel MethodAssigning Callback Phone Numbers Calling Procedure Callback Security Commands Default DescriptionTroubleshooting None of the Indicators LightModem Does Not Respond to Commands Modem Cannot Connect When DialingModem Cannot Connect When Answering Modem Disconnects While OnlineThere Are Garbage Characters on the Monitor File Transfer Is Slower Than It Should BeData Is Being Lost Modem Doesn’t Work with Caller IDAppendix a Regulatory Compliance FCC Part 68 TelecomInternational Modem Restrictions EMC, Safety, and R&TTE Directive ComplianceCanadian Limitations Notice New Zealand Telecom Warning Notice South African NoticeRepair Procedures for U.S. and Canadian Customers Appendix B Warranty, Service, Technical SupportMulti-Tech Warranty Statement Repair Procedures for International CustomersRepair Procedures for International Distributors Replacement PartsIntroduction Upgrade OverviewAppendix C- Upgrading Firmware Identify the Modem FirmwareUpgrade the Modem’s Firmware Download the Upgrade FileExtract the Upgrade Files Clear Your Stored ParametersRestore Your Parameters Using the Modem to Call the Internet Appendix D Installing a Modem Under LinuxInstallation Standard Linux Serial Port DefinitionsCalling the ISP Answering CallsAppendix E Pin Descriptions RS-232 Pin DescriptionsRS-232 Cable Pinouts Leased Line PinoutsWeee Directive Index #DBRegisters
Related manuals
Manual 55 pages 15.82 Kb

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.