Chapter 3 – Using the Front Panel

CALLBACK SECURITY

Use the Æ and Enter buttons to turn callback security on or off. Same as the #DB0 and #DB1 commands. For more information about callback security, see Chapter 6, “Callback Security.”

PASSWORD SETUP

Use to enter callback security passwords in memory locations 1–30. Each password must be six to ten characters in length. To scroll through a list of digits and characters, press the Ç Å and È buttons. To go to the next position, press the Æ button. To back up or to exit without saving, press the Æ button several times. To save the password, press the Enter button. Same as the #CBP= command.

CALLBACK NUMBER

Use to enter callback security phone numbers in memory locations 1–30. Each number can be up to 30 characters long. Same as the #CBN= command. Note: Only 16 characters can be displayed at a time. To see characters 17–30, press the È button. To go to the previous LCD, press the Å button. To go to the next LCD, press the Æ button.

S-REGISTER OPTIONS

Use the Æ, È, and Enter buttons to display the current S-register values and enter new values. Same as the Sr? and Sr=n commands.

VIEW S-REGISTER SETTINGS

Use the Æ È Ç Å and Enter buttons to select the number of the S-register whose value you want displayed. To scroll through a list of digits, press the ÇÅ and È buttons. To go to the next position, press the Æ button. To back up or to exit without saving, press the Æ button several times. To display the value, press the Enter button. Same as the Sr? command.

SET S-REGISTER

Use the Æ È Ç Å and Enter buttons to select the number of the S-register whose value you want to change, and the value you want to enter. To scroll through a list of digits, press the ÇÅ and È buttons. To go to the next position, press the Æ button. To back up or to exit without saving, press the Æ button several times. Same as the Sr=n command.

MONITOR OPTIONS

Use the Æ È and Enter buttons to display line quality and the line signal-to-noise ratio.

LINE QUALITY

Use the Æ and Enter buttons to display line signal quality as a three-digit number. The higher order byte of the EQM value is displayed. Based on the EQM value, retrain or fallback/fall forward may be initiated if enabled by %E1 or %E2. Same as the %Q command.

SIGNAL TO NOISE RATIO

Use the Æ and Enter buttons to display the line signal-to-noise ratio in dB.

Multi-Tech Systems, Inc. MT5600BA-V92 User Guide

26

Image 26
Contents MultiModem Revision Date Description Table of Contents Product Description Product Description FeaturesFeatures Safety Warnings About AT CommandsTechnical Specifications Modem CompatibilityOperating Temperature Connect the Modem to Your System InstallationTwo-Wire or Four-Wire Leased Line Connection Connect the Modem to Your PCPower-On Test Install the Modem DriverConnect the Modem to the AC Power Outlet Installing the Modem DriverSetting Your Country or Region Code Using the LCD Panel Country or Region CodesUsing the Global Wizard Using AT CommandsInstall PhoneTools LED Indicators Using the Front PanelModem Configuration Liquid Crystal Display LCD Option SelectionStatus Trunk Basic Options Trunk Basic Options Trunk Advanced Options Trunk Advanced Options Trunk Remote Configuration Options Trunk Diagnostic Options TrunkPhone Number Memory Options Trunk Caller ID Options TrunkSetting Country/Region Codes Trunk Caller ID Region SelectFunctionality of Menu Options StatusBasic Options Online OptionsCommand Mode Options Advanced Options RS232 OptionsCallback Security Phone Number Memory Options Remote Configuration OptionsDiagnostic Options Caller ID Options Region Select OptionsTwo-Wire / Four-Wire Setup Leased Line OperationFour-Wire Setup Dial BackupDial Backup and Leased Line Restore Setup Setup Changing the Remote Configuration Password Remote ConfigurationBasic Procedure Changing the Remote Escape Character Turning Callback Security On and Off Setup ProceduresCallback Security Assigning Callback Passwords Front Panel MethodAssigning Callback Phone Numbers Calling Procedure Callback Security Commands Default DescriptionTroubleshooting None of the Indicators LightModem Does Not Respond to Commands Modem Cannot Connect When DialingModem Cannot Connect When Answering Modem Disconnects While OnlineThere Are Garbage Characters on the Monitor File Transfer Is Slower Than It Should BeData Is Being Lost Modem Doesn’t Work with Caller IDAppendix a Regulatory Compliance FCC Part 68 TelecomInternational Modem Restrictions EMC, Safety, and R&TTE Directive ComplianceCanadian Limitations Notice New Zealand Telecom Warning Notice South African NoticeRepair Procedures for U.S. and Canadian Customers Appendix B Warranty, Service, Technical SupportMulti-Tech Warranty Statement Repair Procedures for International CustomersRepair Procedures for International Distributors Replacement PartsIntroduction Upgrade OverviewAppendix C- Upgrading Firmware Identify the Modem FirmwareUpgrade the Modem’s Firmware Download the Upgrade FileExtract the Upgrade Files Clear Your Stored ParametersRestore Your Parameters Using the Modem to Call the Internet Appendix D Installing a Modem Under LinuxInstallation Standard Linux Serial Port DefinitionsCalling the ISP Answering CallsAppendix E Pin Descriptions RS-232 Pin DescriptionsRS-232 Cable Pinouts Leased Line PinoutsWeee Directive Index #DBRegisters
Related manuals
Manual 55 pages 15.82 Kb

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.