Multi-Tech Systems MT5600BA-V92 manual Dial Backup and Leased Line Restore Setup

Page 31

Chapter 4 – Leased Line Operation

Dial Backup and Leased Line Restore Setup

1.Connect a telephone cable to the LINE jack of an MT5600BA-V92 modem set up for leased line operation. Connect the other end of the cable to a standard dialup line jack.

2.Turn on the modem.

3.Starting at the STATUS LCD, press the following buttons on the front panel: È, È, Æ, È, Æ, Æ, Æ. The ENTER NUMBER LCD appears.

4.Press the ÇÅ or È button several times to select the first digit in the dial backup telephone number.

5.Press the Æ button to go to the next digit in the number.

Note: To backspace or to cancel an entry, press Æ several times.

6.The number can be up to 30 characters in length. Repeat steps 4 and 5 until the number is entered, and then press the Enter button to store it. The DIAL BACKUP # STORED LCD appears.

7.Press the Enter button again to go to the DIAL BACKUP NUMBER LCD. Note: Steps 8 through 15 are optional.

8.To change the default restore time, press È to go to the TIME TO RESTORE (S15) LCD, then press Æ, Æ. The ENTER TIME IN MINUTES LCD appears.

9.Press the ÇÅ or È button several times to select the first digit in the number.

10.Press the Æ button to go to the next digit in the number.

11.Repeat steps 9 and 10 until you have entered a value between 10 and 255, or 0 to disable dial backup, and then press the Enter button to store it. The TIME STORED LCD appears.

12.Press the Enter button to return to the TIME TO RESTORE (S15) LCD.

13.To change the default dial backup time, press È to go to the DIAL BACKUP TIME (S17) LCD, then press Æ, Æ. The ENTER TIME IN MINUTES LCD appears.

14.Repeat steps 9 and 10 until you have entered a value between 0 and 255, and then press the Enter button to store it. The TIME STORED LCD appears.

15.Press the Enter button again to return to the DIAL BACKUP TIME (S17) LCD.

16.Dial backup and leased line restore setup is complete.

Notes:

Registers S15 and S17 can also be changed using the Sr=n AT command. See the AT Command Reference Guide on the CD that was shipped with your modem.

The dial backup number can be displayed only 16 characters at a time. To see characters 17–30, press the È button. To go to the previous LCD, press the Å button. To go to the next LCD, press the Æ button.

Multi-Tech Systems, Inc. MT5600BA-V92 User Guide

31

Image 31
Contents MultiModem Revision Date Description Table of Contents Features Product Description FeaturesProduct Description About AT Commands Safety WarningsModem Compatibility Technical SpecificationsOperating Temperature Connect the Modem to Your PC InstallationTwo-Wire or Four-Wire Leased Line Connection Connect the Modem to Your SystemInstalling the Modem Driver Install the Modem DriverConnect the Modem to the AC Power Outlet Power-On TestUsing the LCD Panel Country or Region Codes Setting Your Country or Region CodeUsing AT Commands Using the Global WizardInstall PhoneTools Modem Configuration Using the Front PanelLED Indicators Option Selection Liquid Crystal Display LCDStatus Trunk Basic Options Trunk Basic Options Trunk Advanced Options Trunk Diagnostic Options Trunk Advanced Options Trunk Remote Configuration Options TrunkCaller ID Options Trunk Phone Number Memory Options TrunkCaller ID Region Select Setting Country/Region Codes TrunkStatus Functionality of Menu OptionsOnline Options Basic OptionsCommand Mode Options RS232 Options Advanced OptionsCallback Security Diagnostic Options Remote Configuration OptionsPhone Number Memory Options Region Select Options Caller ID OptionsLeased Line Operation Two-Wire / Four-Wire SetupDial Backup Four-Wire SetupDial Backup and Leased Line Restore Setup Basic Procedure Remote ConfigurationSetup Changing the Remote Configuration Password Changing the Remote Escape Character Callback Security Setup ProceduresTurning Callback Security On and Off Front Panel Method Assigning Callback PasswordsAssigning Callback Phone Numbers Calling Procedure Default Description Callback Security CommandsNone of the Indicators Light TroubleshootingModem Cannot Connect When Dialing Modem Does Not Respond to CommandsModem Disconnects While Online Modem Cannot Connect When AnsweringModem Doesn’t Work with Caller ID File Transfer Is Slower Than It Should BeData Is Being Lost There Are Garbage Characters on the MonitorFCC Part 68 Telecom Appendix a Regulatory ComplianceCanadian Limitations Notice EMC, Safety, and R&TTE Directive ComplianceInternational Modem Restrictions South African Notice New Zealand Telecom Warning NoticeRepair Procedures for International Customers Appendix B Warranty, Service, Technical SupportMulti-Tech Warranty Statement Repair Procedures for U.S. and Canadian CustomersReplacement Parts Repair Procedures for International DistributorsIdentify the Modem Firmware Upgrade OverviewAppendix C- Upgrading Firmware IntroductionClear Your Stored Parameters Download the Upgrade FileExtract the Upgrade Files Upgrade the Modem’s FirmwareRestore Your Parameters Standard Linux Serial Port Definitions Appendix D Installing a Modem Under LinuxInstallation Using the Modem to Call the InternetAnswering Calls Calling the ISPRS-232 Pin Descriptions Appendix E Pin DescriptionsLeased Line Pinouts RS-232 Cable PinoutsWeee Directive #DB IndexRegisters
Related manuals
Manual 55 pages 15.82 Kb

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.