Multi-Tech Systems MT5600BA-V92 manual Assigning Callback Phone Numbers

Page 36

Chapter 6 – Callback Security

Assigning Callback Phone Numbers

AT Command Method

1.Open a data communication program, such as HyperTerminal.

2.To store a callback phone number in the first memory location, type

AT#CBN01=xxxxxxxxxx, where xxxxxxxxxx is the dialing string, and press ENTER. The dialing string can include the digits 0 through 9 and any of the following characters: #, *, comma (,), semicolon (;), W, A, B, C, and D. Up to 30 characters can be used. Example: AT#CBN01=9,16127853000.

If a direct connection with password protection, but without hangup and callback, is desired, the first character in the dialing string should be a hyphen (-).

3.To store a callback phone number in the second memory location, type

AT#CBN02=xxxxxxxxxx, where xxxxxxxxxx is the dialing string, and press ENTER. Note that the memory location number in the command is incremented by one.

4.Repeat as many times as necessary, through memory location 30, until all dialing strings have been entered.

Front Panel Method

1.Turn on the modem.

2.Starting at the STATUS LCD, press the following buttons on the front panel: È, È, Æ, È, È, Æ, È, È, Æ. The ENTER NUMBER #1? LCD appears.

3.Press the Enter button on the front panel to select memory location 1. The ENTER NUMBER LCD appears.

4.Press the ÇÅ or È button several times to select the first character. If a direct connection, without hangup and callback, is desired, the first character in the dialing string should be a hyphen (-).

5.Press the Æ button to go to the next character in the dialing string. Note: To backspace or to cancel an entry, press Æ several times.

6.The number can be up to 30 characters in length. Repeat steps 4 and 5 until the number is entered, and then press the Enter button to store it. The NUMBER STORED LCD should appear.

7.Press the Enter button again to go to the CALLBACK NUMBER LCD.

8.Press Æ, Æ to go to the ENTER NUMBER #2? LCD.

9.Repeat steps 3–7 to enter the next number.

10.Repeat as many times as necessary, up to memory location 30, until all numbers have been entered.

Warning: There is no way to review an entry to confirm that it has been entered correctly. If you attempt to look at a number entry by pressing the Enter button for an ENTER NUMBER #n? LCD, it is possible for you to accidentally erase the entry.

Multi-Tech Systems, Inc. MT5600BA-V92 User Guide

36

Image 36
Contents MultiModem Revision Date Description Table of Contents Product Description Features FeaturesProduct Description Safety Warnings About AT CommandsTechnical Specifications Modem CompatibilityOperating Temperature Installation Two-Wire or Four-Wire Leased Line ConnectionConnect the Modem to Your System Connect the Modem to Your PCInstall the Modem Driver Connect the Modem to the AC Power OutletPower-On Test Installing the Modem DriverSetting Your Country or Region Code Using the LCD Panel Country or Region CodesUsing the Global Wizard Using AT CommandsInstall PhoneTools Using the Front Panel Modem ConfigurationLED Indicators Liquid Crystal Display LCD Option SelectionStatus Trunk Basic Options Trunk Basic Options Trunk Advanced Options Trunk Advanced Options Trunk Remote Configuration Options Trunk Diagnostic Options TrunkPhone Number Memory Options Trunk Caller ID Options TrunkSetting Country/Region Codes Trunk Caller ID Region SelectFunctionality of Menu Options StatusBasic Options Online OptionsCommand Mode Options Advanced Options RS232 OptionsCallback Security Remote Configuration Options Diagnostic OptionsPhone Number Memory Options Caller ID Options Region Select OptionsTwo-Wire / Four-Wire Setup Leased Line OperationFour-Wire Setup Dial BackupDial Backup and Leased Line Restore Setup Remote Configuration Basic ProcedureSetup Changing the Remote Configuration Password Changing the Remote Escape Character Setup Procedures Callback SecurityTurning Callback Security On and Off Assigning Callback Passwords Front Panel MethodAssigning Callback Phone Numbers Calling Procedure Callback Security Commands Default DescriptionTroubleshooting None of the Indicators LightModem Does Not Respond to Commands Modem Cannot Connect When DialingModem Cannot Connect When Answering Modem Disconnects While OnlineFile Transfer Is Slower Than It Should Be Data Is Being LostThere Are Garbage Characters on the Monitor Modem Doesn’t Work with Caller IDAppendix a Regulatory Compliance FCC Part 68 TelecomEMC, Safety, and R&TTE Directive Compliance Canadian Limitations NoticeInternational Modem Restrictions New Zealand Telecom Warning Notice South African NoticeAppendix B Warranty, Service, Technical Support Multi-Tech Warranty StatementRepair Procedures for U.S. and Canadian Customers Repair Procedures for International CustomersRepair Procedures for International Distributors Replacement PartsUpgrade Overview Appendix C- Upgrading FirmwareIntroduction Identify the Modem FirmwareDownload the Upgrade File Extract the Upgrade FilesUpgrade the Modem’s Firmware Clear Your Stored ParametersRestore Your Parameters Appendix D Installing a Modem Under Linux InstallationUsing the Modem to Call the Internet Standard Linux Serial Port DefinitionsCalling the ISP Answering CallsAppendix E Pin Descriptions RS-232 Pin DescriptionsRS-232 Cable Pinouts Leased Line PinoutsWeee Directive Index #DBRegisters
Related manuals
Manual 55 pages 15.82 Kb

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.