Multi-Tech Systems MT5600BA-V92 manual Basic Options, Online Options

Page 23

Chapter 3 – Using the Front Panel

Basic Options

The following LCDs are used to configure the modem’s basic operating conditions.

ONLINE OPTIONS

The following LCDs are used to configure the online operation of the modem:

LINE TYPE OPTIONS

Use the Æ and Enter buttons to select from the following line types: dial-up (PSTN), two-wire leased line originate or answer, and four-wire leased line originate or answer.

ERROR CORRECTION OPTIONS

Use the Æ and Enter buttons to turn error correction on or off, or to select automatic error correction. Same as the &E0, &E1, and &E2 commands.

FLOW CONTROL OPTIONS

Use the Æ and Enter buttons to select no flow control, hardware flow control, or software flow control. Same as the &E3, &E4, and &E5 commands.

DIALING OPTIONS

The following LCDs are used to configure dialing options or to dial manually.

TONE/PULSE

Use the Æ and Enter buttons to select between DTMF tone dialing and pulse dialing. Same as the T and P commands.

BLIND/SMART DIAL OPTIONS

Use the Æ and Enter buttons to select blind dialing, in which the modem sends the OK, CONNECT, RING, NO CARRIER, ERROR and NO ANSWER messages to the computer and does not look for a dial tone or busy signal, or smart dialing, in which the modem sends all messages to the computer, including NO DIALTONE and BUSY. Same as the X0 and X4 commands.

DIAL NUMBER

Use the front panel buttons to enter a phone number and dial it. To scroll through a list of digits and characters, press the Å and buttons. To go to the next position, press the Æ button. To back up or to exit without dialing, press the Æ button several times. To dial the number, press the Enter button. Same as the D command.

DTR DIALING

Use the Æ and Enter buttons to enable or disable DTR dialing. DTR dialing is popular in synchronous applications. In DTR dialing, the modem automatically dials the number stored in memory location 0 when it detects a high DTR (Data Terminal Ready) signal on the RS-232 interface. The DTR signal must remain high for the duration of the call. To store the DTR dialing number, use the &Z0= command or the ENTER PHONE #0 menu option.

Note: Plug and Play does not function if DTR dialing is enabled. DTR is used during Plug and Play, and DTR dialing interferes with it.

Multi-Tech Systems, Inc. MT5600BA-V92 User Guide

23

Image 23
Contents MultiModem Revision Date Description Table of Contents Product Description Product Description FeaturesFeatures About AT Commands Safety WarningsModem Compatibility Technical SpecificationsOperating Temperature Connect the Modem to Your PC InstallationTwo-Wire or Four-Wire Leased Line Connection Connect the Modem to Your SystemInstalling the Modem Driver Install the Modem DriverConnect the Modem to the AC Power Outlet Power-On TestUsing the LCD Panel Country or Region Codes Setting Your Country or Region CodeUsing AT Commands Using the Global WizardInstall PhoneTools LED Indicators Using the Front PanelModem Configuration Option Selection Liquid Crystal Display LCDStatus Trunk Basic Options Trunk Basic Options Trunk Advanced Options Trunk Diagnostic Options Trunk Advanced Options Trunk Remote Configuration Options TrunkCaller ID Options Trunk Phone Number Memory Options TrunkCaller ID Region Select Setting Country/Region Codes TrunkStatus Functionality of Menu OptionsOnline Options Basic OptionsCommand Mode Options RS232 Options Advanced OptionsCallback Security Phone Number Memory Options Remote Configuration OptionsDiagnostic Options Region Select Options Caller ID OptionsLeased Line Operation Two-Wire / Four-Wire SetupDial Backup Four-Wire SetupDial Backup and Leased Line Restore Setup Setup Changing the Remote Configuration Password Remote ConfigurationBasic Procedure Changing the Remote Escape Character Turning Callback Security On and Off Setup ProceduresCallback Security Front Panel Method Assigning Callback PasswordsAssigning Callback Phone Numbers Calling Procedure Default Description Callback Security CommandsNone of the Indicators Light TroubleshootingModem Cannot Connect When Dialing Modem Does Not Respond to CommandsModem Disconnects While Online Modem Cannot Connect When AnsweringModem Doesn’t Work with Caller ID File Transfer Is Slower Than It Should BeData Is Being Lost There Are Garbage Characters on the MonitorFCC Part 68 Telecom Appendix a Regulatory ComplianceInternational Modem Restrictions EMC, Safety, and R&TTE Directive ComplianceCanadian Limitations Notice South African Notice New Zealand Telecom Warning NoticeRepair Procedures for International Customers Appendix B Warranty, Service, Technical SupportMulti-Tech Warranty Statement Repair Procedures for U.S. and Canadian CustomersReplacement Parts Repair Procedures for International DistributorsIdentify the Modem Firmware Upgrade OverviewAppendix C- Upgrading Firmware IntroductionClear Your Stored Parameters Download the Upgrade FileExtract the Upgrade Files Upgrade the Modem’s FirmwareRestore Your Parameters Standard Linux Serial Port Definitions Appendix D Installing a Modem Under LinuxInstallation Using the Modem to Call the InternetAnswering Calls Calling the ISPRS-232 Pin Descriptions Appendix E Pin DescriptionsLeased Line Pinouts RS-232 Cable PinoutsWeee Directive #DB IndexRegisters
Related manuals
Manual 55 pages 15.82 Kb

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.