Multi-Tech Systems MT5600BA-V92 manual Remote Configuration, Basic Procedure

Page 32

Chapter 5 – Remote Configuration

Chapter 5 - Remote Configuration

Remote configuration is a network management tool that allows you to configure modems anywhere in your network from one location. With password-protected remote configuration, you can issue AT commands to a remote MultiModem II modem for maintenance or troubleshooting as if you were on-site.

Basic Procedure

The following steps are valid regardless of whether the connection is established by the local or the remote MultiModem II modem.

1.Establish a data connection with a remote MT5600BA-V92 modem.

2.Send three asterisks to initiate remote configuration. The remote modem responds:

Online Remote Access Remote password:

3.Type the remote configuration password, and then press ENTER. The default is “MULTITECH.” It is not case-sensitive.

If the password is incorrect, the word CONNECT appears, and the local modem is returned to online mode.

If the password is correct, an >AT_ command prompt appears.

4.Type AT commands to configure the remote modem. It is not necessary to precede the commands with “AT.”

5.When you have finished configuring the remote modem, type *E and press ENTER to exit remote configuration mode and return to online data mode. You can now break the connection in the normal way.

Note: The dialing command is not allowed in remote configuration mode.

Setup

Multi-Tech modems are shipped with a default setup password (MULTITECH). Because anyone who has an owner’s manual knows the default setup password, for security you should change the password and possibly also the remote configuration escape character.

Changing the Remote Configuration Password

The remote configuration password can be changed only from the front panel of the modem:

1.Turn on the modem.

2.Starting at the STATUS LCD, press È È È Æ Æ È Æ to access the ENTER PASSWORD LCD.

3.To change the password, press ÇÅ or È to select the first character of the password, and then press Æ to go to the next character. Repeat until you have entered the entire password.

4.To cancel the new password, press Æ until the password is erased. To save the new password, press the Enter button. The next time you remotely configure the modem you must use the new password.

Multi-Tech Systems, Inc. MT5600BA-V92 User Guide

32

Image 32
Contents MultiModem Revision Date Description Table of Contents Product Description Product Description FeaturesFeatures Safety Warnings About AT CommandsTechnical Specifications Modem CompatibilityOperating Temperature Installation Two-Wire or Four-Wire Leased Line ConnectionConnect the Modem to Your System Connect the Modem to Your PCInstall the Modem Driver Connect the Modem to the AC Power OutletPower-On Test Installing the Modem DriverSetting Your Country or Region Code Using the LCD Panel Country or Region CodesUsing the Global Wizard Using AT CommandsInstall PhoneTools LED Indicators Using the Front PanelModem Configuration Liquid Crystal Display LCD Option SelectionStatus Trunk Basic Options Trunk Basic Options Trunk Advanced Options Trunk Advanced Options Trunk Remote Configuration Options Trunk Diagnostic Options TrunkPhone Number Memory Options Trunk Caller ID Options TrunkSetting Country/Region Codes Trunk Caller ID Region SelectFunctionality of Menu Options StatusBasic Options Online OptionsCommand Mode Options Advanced Options RS232 OptionsCallback Security Phone Number Memory Options Remote Configuration OptionsDiagnostic Options Caller ID Options Region Select OptionsTwo-Wire / Four-Wire Setup Leased Line OperationFour-Wire Setup Dial BackupDial Backup and Leased Line Restore Setup Setup Changing the Remote Configuration Password Remote ConfigurationBasic Procedure Changing the Remote Escape Character Turning Callback Security On and Off Setup ProceduresCallback Security Assigning Callback Passwords Front Panel MethodAssigning Callback Phone Numbers Calling Procedure Callback Security Commands Default DescriptionTroubleshooting None of the Indicators LightModem Does Not Respond to Commands Modem Cannot Connect When DialingModem Cannot Connect When Answering Modem Disconnects While OnlineFile Transfer Is Slower Than It Should Be Data Is Being LostThere Are Garbage Characters on the Monitor Modem Doesn’t Work with Caller IDAppendix a Regulatory Compliance FCC Part 68 TelecomInternational Modem Restrictions EMC, Safety, and R&TTE Directive ComplianceCanadian Limitations Notice New Zealand Telecom Warning Notice South African NoticeAppendix B Warranty, Service, Technical Support Multi-Tech Warranty StatementRepair Procedures for U.S. and Canadian Customers Repair Procedures for International CustomersRepair Procedures for International Distributors Replacement PartsUpgrade Overview Appendix C- Upgrading FirmwareIntroduction Identify the Modem FirmwareDownload the Upgrade File Extract the Upgrade FilesUpgrade the Modem’s Firmware Clear Your Stored ParametersRestore Your Parameters Appendix D Installing a Modem Under Linux InstallationUsing the Modem to Call the Internet Standard Linux Serial Port DefinitionsCalling the ISP Answering CallsAppendix E Pin Descriptions RS-232 Pin DescriptionsRS-232 Cable Pinouts Leased Line PinoutsWeee Directive Index #DBRegisters
Related manuals
Manual 55 pages 15.82 Kb

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.