Liebert NfinityTM manual Main Menu, UPS Status Event Log Module Replacement, Display Date/Time

Page 24

Operating Instructions

3.5Main Menu

After initialization, the button will take you to the Main Menu. From here you may check on the status of the UPS, review the event log and active alarms, configure your UPS and even receive instructions on replacing modules. The Main Menu is divided into eight sub-menus as shown below:

Main Menu

>UPS Status

UPS Configuration Display Date/Time Event Log Active Alarms Transfer to Bypass Module Replacement Service Tools

UPS Status

Event Log

 

 

Module Replacement

UPS Status

Event: xxx/xxx

xx

Module Replacement

Present Load

event message

 

Ctrl w/ Redundant

Redundant Status

event message

 

Ctrl w/o Redundant

Battery Status

DD/MMM/YYYY

HH:MM:SS

Pwr w/ Redundant

Volts/Amps/kVA

 

 

 

Pwr w/o Redundant

UPS Frequency

 

 

 

Battery Module

Bypass Information

 

 

 

 

UPS Information

 

 

 

 

Module Information

 

 

 

 

UPS Configuration

Active Alarms

 

 

Service Tools

UPS Configuration

Active Alarms Message

Service Tools

Review Settings

 

 

 

UPS Test

Change Settings

 

 

 

Clear Failures

Service Mode

 

 

 

BM Cell Replacement

 

 

 

 

Reset Battery Stats

 

 

 

 

Reset Bypass Stats

Display Date/Time

Date/Time xx/xx/xxxx xx:xx:xx mm/dd/yyyy hh:mm:ss

Transfer to Bypass

Press for bypass Press ESC to cancel

Use the and buttons to select the desired menu item and press to access the appropriate submenu.

20

Image 24
Contents Nfinity Power System Page Table of Contents Figures Important Safety Instructions Glossary of Symbols Features General DescriptionSystem Description Standard ComponentsNfinity weight and dimensions Front and back views 12 bay model shownNormal Mode Backup ModeAuto Restart Mode Bypass ModeMajor Components Unit FrameUser Interface Module System Control ModulePower Module Battery ModuleRequired Setup Equipment InspectionEnvironment Site PreparationUnloading Unloading the UPSStationary Mounting Cable Installation Wiring PreparationInput Wiring TB1 Output Wiring TB3Grounding Conductor Installation Connecting to External Panel Boards Input ProtectionLoad Rating Circuit BreakerSetup 1 210 VAC Setup 2 210/105 VAC210 VAC 210VAC and/or 105VACRepo switch connections Repo ConnectionCommunications COM PortsCOM1 Relay Contacts COM2 SerialControls and Indicators Fault/Warning and Status LEDsDisplay Controls ButtonsStatus LED Modes Navigating the MenuOperating Procedures Start-Up and InitializationManual Transfer to Bypass Shutting Down the UPSUPS Status Event Log Module Replacement UPS Configuration Active Alarms Service ToolsMain Menu Display Date/TimeUPS Status Screen UPS Configuration Screen Review Settings Change Configuration Settings Change Settings Menu Change SettingsAuto Restart Mode Auto Restart DelayInterval Start DayDST Mode Alarm ModeSet Date/Time ThresholdBypass Alarm Mode Enable Disable UPS Configuration Screen Service Mode Menu Service ModeDisplay Date/Time Active Alarms Event LogTransfer to Bypass Module Replacement Service Tools for Liebert Global Services Engineers Clear FailuresActive Alarms User Interface Text Cause ActionOperation Power Module Battery Module Guide to LEDsModule LED Indication Control ModuleModule Replacement Removing ModulesAdding or Replacing Modules Replacing the User InterfaceMaintenance Scheduled MaintenanceProper Care Replacing Fan FiltersProduct Warranty Registration SpecificationsSpecifications Page Technical Support/Service Company Behind the ProductsLocations