Liebert NfinityTM manual Front and back views 12 bay model shown, Nfinity weight and dimensions

Page 8

Introduction

Figure 1 Front and back views (12 bay model shown)

Power

Module

Bays

Battery

Module

Bays

Manual Bypass Switch (SW1)

Intake Cooling Fans

User Interface

Control

REPO

Intellislot™

Switch (SW2)

Connection

Communications Ports

 

 

 

 

 

 

 

!

ESC

DB-9

Communication

Ports

Output Power

Terminal

Input Power

Terminal

Input Earth

Terminal

Input Circuit

Breaker (CB1)

External Battery

Connection

FRONT VIEW

BACK VIEW

with bezels

with access

removed

plates removed

Refer to the table below for size and fully populated weight considerations.

 

Table 1

Nfinity weight and dimensions

Model

 

Max Weight - lb (kg)

W x D x H - in. (mm)

 

 

 

 

 

8 bay

 

 

855 (388)

20 x 28 x 40 (508 x 711 x 1016)

 

 

 

 

 

12 bay

 

 

1176 (534)

20 x 28 x 53 (508 x 711 x 1346)

 

 

 

 

 

4

Image 8
Contents Nfinity Power System Page Table of Contents Figures Important Safety Instructions Glossary of Symbols Features General DescriptionSystem Description Standard ComponentsNfinity weight and dimensions Front and back views 12 bay model shownNormal Mode Backup ModeAuto Restart Mode Bypass ModeMajor Components Unit FrameUser Interface Module System Control ModulePower Module Battery ModuleRequired Setup Equipment InspectionEnvironment Site PreparationUnloading Unloading the UPSStationary Mounting Cable Installation Wiring PreparationGrounding Conductor Installation Input Wiring TB1Output Wiring TB3 Connecting to External Panel Boards Input ProtectionLoad Rating Circuit BreakerSetup 1 210 VAC Setup 2 210/105 VAC210 VAC 210VAC and/or 105VACRepo switch connections Repo ConnectionCommunications COM PortsCOM1 Relay Contacts COM2 SerialControls and Indicators Fault/Warning and Status LEDsDisplay Controls ButtonsStatus LED Modes Navigating the MenuOperating Procedures Start-Up and InitializationManual Transfer to Bypass Shutting Down the UPSUPS Status Event Log Module Replacement UPS Configuration Active Alarms Service ToolsMain Menu Display Date/TimeUPS Status Screen UPS Configuration Screen Review Settings Change Configuration Settings Change Settings Menu Change SettingsAuto Restart Mode Auto Restart DelayInterval Start DayDST Mode Alarm ModeSet Date/Time ThresholdBypass Alarm Mode Enable Disable Display Date/Time UPS Configuration Screen Service Mode MenuService Mode Transfer to Bypass Active AlarmsEvent Log Module Replacement Service Tools for Liebert Global Services Engineers Clear FailuresActive Alarms User Interface Text Cause ActionOperation Power Module Battery Module Guide to LEDsModule LED Indication Control ModuleModule Replacement Removing ModulesAdding or Replacing Modules Replacing the User InterfaceMaintenance Scheduled MaintenanceProper Care Replacing Fan FiltersProduct Warranty Registration SpecificationsSpecifications Page Locations Technical Support/ServiceCompany Behind the Products