Lantronix 900-653-R manual Password Required, Modem Escape Sequence, Pass Through, Active Connect

Page 32

 

 

 

5: Configuration Using Web Manager

 

 

 

 

 

Password Required

Determines whether a password is required for an incoming passive

 

 

connection. This field is not available when a password is set for Telnet

 

 

mode. The default setting is No.

 

Password

If Password Required was set to Yes, enter the password for passive

 

 

connections.

 

Modem Escape Sequence

Disable or enable the xDirect’s ability to send the escape sequence. The

 

Pass Through

default is Yes (send the escape sequence).

 

 

 

 

Connect Mode: Active Connection

 

 

 

 

 

Active Connect

 

Select None (default) to disable Active Connect. Otherwise, indicate

 

 

 

the connection type from the drop-down list:

 

 

 

With Any Character: Attempts to connect when any character is

 

 

 

received from the serial port.

 

 

 

With Active Mdm Ctrl In: Accepts external connection requests only

 

 

 

when the Modem Control In input is asserted.

 

 

 

With Start Character: Attempts to connect when it receives a specific

 

 

 

start character from the serial port. The default start character is

 

 

 

carriage return.

 

 

 

Manual Connection: Attempts to connect when directed by a

 

 

 

command string received from the serial port.

 

 

 

Auto Start: Automatically connects to the remote IP address and port

 

 

 

after booting up.

 

Start Character

 

If Active Connect is set to With Start Character, enter the start character

 

 

 

in this field. The default setting is 0D.

 

Modem Mode

 

Indicates the on-screen response type when in Modem Mode (if Modem

 

 

 

Mode is enabled). The default setting is None.

 

Show IP Address After RING

Indicates whether to display the remote IP address upon connection. The

 

 

 

default setting is Yes.

 

 

 

 

Endpoint Configuration

 

 

 

 

 

 

 

Local Port

 

Enter the local port number.

 

Auto increment for active

 

Select to auto-increment the local port number for new outgoing

 

connect

 

connections. The range of auto-incremented port numbers is 50,000 to

 

 

 

59,999 and loops back to the beginning when the maximum range is

 

 

 

reached. Disabled by default.

 

Remote Port

 

Enter the remote port number.

 

Remote Host

 

Enter the IP address of the remote device.

 

 

 

 

Common Options

 

 

 

 

 

 

 

Telnet Com Port Cntrl

 

This field is available for configuration only when Active Connect is set

 

 

 

to None. Select Enable to permit Telnet communication to the xDirect

 

 

 

unit. The Telnet Com Port Cntrl feature is used in conjunction with the

 

 

 

Com Port Redirector (CPR) utility. (See the CPR online Help for details.)

 

Terminal Name

 

This field is available for configuration only when Telnet Com Port Cntrl

 

 

 

is set to Enable.

 

 

 

Use the terminal name for the Telnet terminal type. Enter only one name.

 

 

 

When this option is enabled, the unit also reacts to the end of record

 

 

 

(EOR) and binary options, which can be used for applications such as

 

 

 

terminal emulation to IBM hosts.

 

 

 

 

xDirect User Guide

32

Image 32
Contents User Guide Warranty Copyright & TrademarkContacts DisclaimerTable of Contents Using this GuideInstallation of xDirect Using DeviceInstallerConfiguration Using Web Manager Configuration Via Telnet or Serial Port Setup ModeSetup Mode Server Configuration Setup Mode Channel ConfigurationMonitor Mode Setup Mode Advanced SettingsFirmware Upgrades Appendix a Troubleshooting and Contact Info Appendix B Connections and PinoutsAppendix E Binary to Hexadecimal Conversions Appendix F ComplianceList of Figures Serial Tunneling ExampleList of Tables Chapter Summary Using this GuidePurpose and Audience Additional Documentation Document DescriptionApplications Key FeaturesIntroduction Introduction Protocol Support Additional FeaturesConfiguration Methods Product Information Label Product LabelInstalling the xDirect Installation of xDirectPackage Contents IP Address Required InformationHardware Address Using DeviceInstaller Installing DeviceInstallerTo install DeviceInstaller Assigning an IP AddressAccessing the xDirect Using DeviceInstaller Viewing the Current ConfigurationTo view the units current settings XDirect Configuration in DeviceInstallerSupports Configurable Pins CommentsDevice Family TypeAssigning the IP Address Serial Port Login Next StepConfiguration Using Web Manager Accessing xDirect Using DeviceInstallerConfiguration Using Web Manager Network Configuration Network ModeAutomatic IP Address Configuration To assign an IP address automaticallyStatic IP Address Configuration Ethernet ConfigurationSelect Use the following IP configuration To assign an IP address manuallyServer Configuration To configure the xDirect device server settingsMonitor Mode @ Bootup CPU Performance ModeConfig Server Port Timeout msHost List Configuration To configure the host listRetry Timeout Retry CounterTo configure the channel’s serial settings Channel 1 ConfigurationSerial Settings Enable Packing Baud RateData Bits ParityAccept Incoming Connection Settings TCPTo configure a channel’s TCP settings Password Required Modem ModeModem Escape Sequence Pass ThroughConnection Settings UDP To configure a channel’s UDP settingsDevice Address Table Datagram TypeUse Broadcast Apply Settings Apply DefaultsConfiguration Via Telnet or Serial Port Setup Mode Accessing Setup ModeTelnet Connection To establish a Telnet connectionPassword Press Enter for Setup Mode Serial Port Connection Exiting Setup ModeTwo options through which to exit setup mode Setup Mode Server Configuration Server Configuration OptionBootP/DHCP/AutoIP options IP AddressSet Gateway IP Address Netmask Number of Bits for Host PartSet DNS Server IP Address Standard IP Network NetmasksChange Telnet Configuration Password Dhcp NameBaudrate Setup Mode Channel ConfigurationChannel 1 Option Interface Mode Interface Mode OptionsCommon Interface Mode Settings FlowConnect Mode Port NumberFlow Control Options Reserved Port NumbersIncoming Connection Connect Mode OptionsConnect Mode Option Manual Connection Address Example ResponseActive Startup Host List Option Hostlist C0.0.0.0/0Autostart Automatic ConnectionModem Mode To enable the hostlistDatagram Type Directed UDPModem Mode Messages Message MeaningSend the Escape Sequence +++ in Modem Mode 10 Modem Mode CommandsModem Mode Function Command Show IP Address after RingDisconnect Mode DisConnMode Auto Increment Source PortRemote IP Address Remote Port12 Flush Mode Options Flush Mode Buffer Flushing11 Disconnect Mode Options Pack Control Packing IntervalTrailing Characters Send CharactersDisConnTime Inactivity Timeout Channel Port PasswordSend Characters Telnet Terminal TypeSetup Mode Advanced Settings Expert Settings OptionARP Cache Timeout In Seconds TCP Keepalive Time In SecondsSecurity Settings Option Snmp Community Name Disable SnmpDisable Telnet Setup Disable Tftp Firmware Update Disable Port 77FE HexDisable Web Server Disable Web SetupDefault Settings Option Enable Enhanced PasswordChannel 1 Configuration Defaults Expert Settings DefaultsSecurity Settings Defaults Setup Mode Advanced SettingsFirmware Upgrades Using Tftp Graphical User InterfaceObtaining Firmware Reloading Firmware Firmware FilesUsing Tftp Command Line Interface To recover firmwareFirmware Upgrades Monitor Mode Entering Monitor Mode Using the Serial PortEntering Monitor Mode Using the Network Port To enter Monitor Mode locallyMonitor Mode Commands Monitor Mode CommandsCommand Command Name Function G0, G1, ....,Ge, GfCommand Response Codes Response MeaningAppendix a Troubleshooting and Contact Info LEDsStatus LED Table A-2 Status LEDRJ45 Ethernet LED Problems and Error MessagesSerial LEDs Using DeviceInstaller Serial Settings on page 29 or Europe, Middle East and Africa Technical SupportUnited States Appendix B Connections and Pinouts Serial Port PinoutsEthernet Connector Pinouts Table B-6 Ethernet RJ45 Connector Pin-OutsPower Jack Mini USB-B Category Description Appendix C Technical SpecificationsTable C-1 xDirect Technical Specifications Appendix C Technical Specifications Appendix D Alternative Ways to Assign an IP Address AutoIPARP and Telnet To assign a temporary IP addressAppendix E Binary to Hexadecimal Conversions Converting Binary to HexadecimalConversion Table Scientific CalculatorAppendix E Binary to Hexadecimal Conversions Safety Appendix F ComplianceManufacturer’s Name & Address Electromagnetic EmissionsAppendix F Compliance RoHS Notice