Magnum | Installation and User Guide (06/03) |
B6.0 ORDERING INFORMATION
To order the optional
Similarly, to order the optional 24VDC, 100VDC, or 125VDC industrial power supply for factory installation and test, add a suffix of
Magnum QS5116-125VDC.
B7.0 TROUBLESHOOTING Please refer to Section 6.0
APPENDIX C: MAGNUM INTERNAL DC DUAL-SOURCE POWER OPTION
C1.0 SPECIFICATIONS - FOR MAGNUM
DC Power Connector: First Source: “A+”,
GND: Terminal for “earth” or ground wire connection to the switch chassis
Input: Two separate sources, each at 36 - 70 VDC
Power Consumption: Model QS5108 & QS5116 :30 watt typical, 50 watts max.
Power Supply (Internal, 24VDC
DC Power Connector: First Source: “A+”,
GND: Terminal for “earth” or ground wire connection to the switch chassis
Input: Two separate sources, each at 20 - 36 VDC
Power Consumption: Model QS5108 & QS5116 : 30 watt typical, 50 watts max.
Power Supply (Internal, 100 and 125VDC
DC Power Connector: First Source: “A+”,
GND: Terminal for “earth” or ground wire connection to the switch chassis
Input: Two separate sources, each at 100 (90 to 160V) or 120 - 160 V range
Power Consumption: Model QS5108 & QS5116: 30 watt typical, 50 watts max.
With the exception of the dual DC input power connections and the power supply, all specifications and configuration options for the Magnum
C2.0
Source power supply are designed for installations where a battery plant is the power source, and where two separate power sources are utilized in order to increase operational uptime and to simplify maintenance.
The functionality of the Magnum
www . GarrettCom . com
47