Magnum | Installation and User Guide (06/03) |
Fiber
Fiber Port,
Manual switch-selections and jumpers
Fiber default:
Copper default:
LEDs: Per Port
LK: Steady ON when media link is operational
ACT: ON with receiver port activity
FDX/HDX: ON =
100/10: ON = 100Mbps speed OFF = 10 Mbps
Operating Environment
Ambient Temperature: 32° to 120° F (0° to 50°C)
Storage Temperature:
Ambient Relative Humidity: 10% to 95%
Packaging
Enclosure: Rugged High strength metal. Suitable for
Dimensions: 1.75 in H x 17.0 in W x 9.13 in D (10.0 in W for QS580)
| 4.45cm H x 43.2cm W x 23.2cm D (25.4 cm W for QS580) |
Weight: | 4.0 lb. (1.8 Kg) for |
Cooling method: Fan cooled, @ 9 cfm
Power Supply (Internal)
AC Power Connector:
Input Voltage: 110 to 240 VAC
Input Frequency: 47 to 63 Hz
Power Consumption: 20 watts typical (8 port model) 35 watts typical (16 port model)
Redundant power supplies available as options
DC Power Supply (Options)
24VDC Power Input Voltage : 20 to 36VDC
125VDC Power Input Voltage : 120 to 160VDC
Std. Terminal Block : “
Power Consumption: same as for AC models, see above
For Dual Source and Redundant DC for
For optional 23” Telco
Agency Approvals
UL listed (UL1950), cUL, CE
Emissions meet FCC Part 15 Class A
Warranty | Three years, return to factory | Made in USA |
www . GarrettCom . com