GE GEK-106465A Packaging and Weight, Type Tests, Category Standard Class Test, Approvals

Page 13

PRODUCT DESCRIPTION

 

 

 

 

2.4.6.

 

PACKAGING AND WEIGHT

Net weight:

2.5 kg

 

 

 

 

 

 

 

 

Packaged:

3.5 kg

 

 

 

 

 

 

 

 

Package dimensions (WxHxD): 30x40x40 cm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.4.7.

TYPE TESTS

 

 

 

 

 

 

 

 

 

 

 

CATEGORY

 

STANDARD

CLASS

TEST

 

 

 

 

 

 

EMC

 

IEC 1000-4-8 EN61000-4-8

IV

Power

frequency

magnetic field

 

 

 

 

 

immunity test.

 

 

 

 

 

 

 

IEC 1000-4-10 EN61000-4-10

4

Damped oscillatory field immunity test

 

 

 

IEC 1000-4-3 IEC60255-22-3

III

Radiated, radio-frequency

 

 

 

 

 

 

 

electromagnetic field immunity test

 

 

 

IEC 1000-4-3

3

Digital radiofrequency

electromagnetic

 

 

 

 

 

field

 

 

 

 

 

 

 

 

IEC 1000-4-2 EN 61000-4-2 IEC60255-

III

Electrostatic discharge immunity test

 

 

 

22-2

 

 

 

 

 

 

 

 

 

 

IEC 1000-4-16

4

Test for immunity to conducted common

 

 

 

 

 

mode disturbances in the frequency

 

 

 

 

 

range 0Hz to 150 kHz immunity test.

 

 

 

IEC 1000-4-5

4

Surge immunity test

 

 

 

 

 

 

IEC 1000-4-12 IEC 60255-22-1

III

Noise 1 MHz. Oscillatory waves

 

 

 

 

 

immunity test.

 

 

 

 

 

 

 

IEC 1000-4-4 EC 61000-4-4 IEC60255-

IV

Electrical

fast

transient/burst immunity

 

 

 

22-4

 

test

 

 

 

 

 

 

 

 

IEC 1000-4-6 IEC60255-22-6

III

Immunity

to

conducted

disturbances,

 

 

 

 

 

induced by radio-frequency fields

 

EMC Emisivity

 

IEC 60255-25 EN55022

B

Conducted and radiated emissions class

 

 

 

 

 

B

 

 

 

 

 

 

Product

 

IEC60255-5

2 kV

Insulation

 

 

 

 

 

 

 

 

IEC60255-5

6kV .5J

Impulse test

 

 

 

 

 

 

 

IEC60255-11; IEC61000-4-29

100 ms

Power supply interruptions

 

 

 

CIO has been designed to comply with the highest existing requirements. More specifically, UNIPEDE recommendations for high voltage substations are followed.

2.4.8. APPROVALS

ISO9001 Registered system.

CE marking: Meets the CE standards relevant for protections.

12

CIO Remote CAN Digital I/O Module

GEK-106465A

Image 13 Contents
CIO Table of Contents Circuit Continuity Supervision Inputs INPUT/OUTPUT Modules DescriptionCIO Front View Important ProceduresIdentification Label A4454P5 Inspection ChecklistAMERICA, Asia and Australia GE Multilin EUROPE, Middle East and Africa GE MultilinSafety Instructions Introduction to F650 and F600 Family of Relays OverviewHardware Architecture Software ArchitectureCommunications Architecture Product Description Summary of FeaturesCIO Description Ordering CodeTechnical Specifications Type Tests Packaging and WeightCategory Standard Class Test ApprovalsModule Description Power supply Input/Output moduleMounting Mechanical DescriptionRear Panel Mounting Rear Cover Description External Connections WiringWiring Diagram for Model CIOH1J1 226B5113F2 Board Option BoardsMixed Termina Inputs Supervision OutputsSUPCOIL2 Operand DescriptionWithout Supervision With Current Supervision with SEAL-IN With Simple Voltage Supervision Circuit Output Breaker Operand Status Internal StateHardware Hardware With Double Voltage Supervision Status of Involved Elements Inputs to F650 52/a 52/bOperand Contact INPUT0015 SUPCOIL2 Software Front IndicatorsUser Interfaces Circuit Supervision Circuit Supervision and Contact SEAL-IN CircuitsContact SEAL-IN INPUT/OUTPUT Boards Settings Control Settings for INPUTS/OUTPUTSGeneral Board Settings Input Logic Settings relative to InputsOutput Logic Settings relative to OutputsINPUTS/OUTPUTS Status Input activation signals Contact InputsInput Status Mixed Board Supervision Board Board F, G, H, J TypeContact Output Activation Signals Contact Output Operates Contact Outputs activation signalsContact Output Status Board F, G, H, JContact Output Resets Contact Output Reset Signals Contact Output ResetsIO Board Status Board StatusVisual Inspection General Considerations on the Power Supply NetworkPower Suply Testing IndicatorsIsolation Tests Source OptionCommunication with the Master Unit Settings/Control Elements/Inputs Outputs/BoardInputs and Outputs Digital InputsCircuit Continuity Supervision Inputs Contact OutputsCoil Latching Circuits