Eizo CG245W user manual Setting the calibration schedule Schedule, Fri/Sat/Sun

Page 35

Setting the calibration schedule [Schedule]

Set the calibration schedule for SelfCalibration.

Attention

• Clock adjustment is necessary for SelfCalibration to operate.

Procedure

1.Choose <Setting> from the SelfCalibration menu, and press .

2.Choose <Schedule> from the Setting menu, and press . The schedule setting menu is displayed.

3.Select the items to change with or , and press .

Setting Item

Setting Range

 

Setting

Starting Time

Off

Set the timing at which SelfCalibration is executed.

 

Power Save

Off

: SelfCalibration is not executed.

 

Immediately

Power Save

: When the time period set in the schedule

 

 

 

has elapsed, it is executed if the mode

 

 

 

initially switches to power save, or if the

 

 

 

power initially switches off.

 

 

Immediately

: When the time period set in the schedule

 

 

 

has elapsed, it is executed immediately.

Setting Type

Type1

Set according to the frequency at which SelfCalibration is

 

Type2

executed.

 

 

Type3

Type1 : Once every few months

 

 

Type2 : Once every few weeks

 

 

Type3 : Once every few hours (monitor usage time)

Interval

Type1 : 1 - 12 months

Set the interval between the completed SelfCalibration and

 

Type2 : 1 - 5 weeks

the next execution. The setting details differ depending on

 

Type3 : 50 - 500 h

the type of <Setting Type> specified.

Week

1st week - 5th week

Set which week to execute SelfCalibration on for the month

 

 

in which calibration is executed.

Day

MON/TUE/WED/THU/

Set which day to execute SelfCalibration on for the week in

 

FRI/SAT/SUN

which calibration is executed.

Time

00:00 - 23:30

Set the time at which SelfCalibration is executed.

*1 Settings that are used frequently can be preset.

4.Adjust using or .

5.Press to exit the adjustment. The calibration schedule is set.

NOTE

The schedule can be set using ColorNavigator. Refer to the ColorNavigator User’s Manual on the CD-ROM.

When the starting time is [Immediately], and the setting type is either [Type1] or [Type2], SelfCalibration is

executed according to schedule even if the power is switched off using

.

When the starting time is “Off”, the SelfCalibration menu shows “Setting Incomplete.” However, SelfCalibration can be executed manually.

Chapter 4 SelfCalibration 35

Image 35
Contents Page Location of Caution Statement Page Cabinet LCD PanelContents HinweiseHinweise zur Auswahl des richtigen Introduction FeaturesControls and Functions To use ColorNavigator Disk contents and software overviewUtility Disk Displaying Menu Adjusting/SettingBasic Operation and Functions Exiting Showing Button GuideFunctions Calibration Setting Screen Resolution Adjusting ScreenMac OS WindowsWindows Vista Windows XPDisplaying Screen Correctly Expanding Signal Output Range Range ExtensionAdjustment Procedure Perform the auto adjustment Windows Page To adjust color gradation automatically Range Adjustment Adjust the color gradationMode Purpose Color AdjustmentTo select the display mode Color Mode Color Mode Icon Function To perform advanced adjustmentsAdjustment items in each mode To adjust the color temperature Temperature To adjust the brightness BrightnessTo adjust the contrast Contrast To adjust the color saturation Saturation To adjust the gamma value GammaTo adjust the hue Hue To enhance the outline of the image Outline Enhancer To adjust the gain value GainTo adjust the black level Black Level To adjust six colors 6 Colors Menu Function Displaying Lower ResolutionsConfiguring moving image performance Overdrive To change screen size Screen SizeLocking Buttons Key Lock Enabling/Disabling Mode Selection Mode PresetSettings Buttons that can be locked Setting Orientation Orientation Setting the Eizo Logo Display LogoSelectable languages Setting Language LanguageSetting Range of Frequency Signal Bandwidth Sets the brightness of the front buttons Indicator To reset color adjustment values Color Reset Restoring the Default Setting Checking Calibration Results Result Executing SelfCalibration CalibrationSetting Item Setting Range Setting Calibration Details SettingSetting the mode to execute SelfCalibration Mode Selection Setting the calibration targetsSet the monitor date and time Setting the monitor date and time Clock AdjustmentFRI/SAT/SUN Setting the calibration schedule ScheduleMonitor Power Indicator Setting the Power Saving Power SaveSignal inputs Standard Problems Possible cause and remedy No picture TroubleshootingShown below Problems Possible cause and remedy Characters are blurredAfterimages appear Remain on the screenStays out Problems Possible cause and remedyCable is not detected. / USB devices Connected to the monitor does not workAttach the monitor to the arm or stand Attaching an ArmConnection examples Connecting More than Two PCs to the MonitorTo switch the input signal Setting Function To set input signal selection Input SelectionRequired System Environment Connection Procedure Setup of USB FunctionMaking Use of USB Universal Serial Bus Displaying monitor information Monitor Info Displaying signal information Signal InfoDisplaying Monitor Information Specifications USB Main default settings factory settingsUnit mm inch Outside DimensionsContact No Signal Remarks Connector Pin AssignmentPin Signal Pin No SignalGlossary Resolution Hdcp High-bandwidth Digital Contents ProtectionPhase Range AdjustmentTmds Transition Minimized Differential Signaling TemperatureVGA Text Preset TimingFor more information, please visit FCC Declaration of Conformity Hinweis zur Ergonomie Limited Warranty Begrenzte Garantie Garantie Limitée Garantía Limitada Garanzia Limitata Begränsad Garanti Περιορισμενη Εγγυηση Ограниченная Гарантия 有限责任保证书 关于电子信息产品污染控制标识