Attaching Cables, Installing Compact Flash Card and DIMM Upgrade Kit

3.Plug the other end of the cable into the appropriate port on the other device. Some cables may be terminated at the other end with two separate connectors, one for each fiber‐optic strand. In this case, ensure that the transmit fiber‐optic strand is connected to the receive port and the receive fiber‐optic strand to the transmit port.

4.To verify link exists, you must first configure the ports for switching or routing. Refer to the Matrix X Router Configuration Guide for more information.

After the chassis has been powered up, verify a link exists by checking that the port RX LED is on (flashing amber, blinking green, or solid green). If the RX LED is off, perform the following steps until it is on:

a.Verify the device at the other end of the segment is ON and linked to the segment.

b.If there are separate fiber‐optic connections on the other device, check the crossover of the cables. Swap cable connections if necessary.

c.Check that the fiber‐optic connection meets prescribed dB loss and cable specifications.

5.Repeat steps 1 through 3, above, until all connections have been made.

6.To remove the LC or MT‐RJ cable connector, press its release tab and pull it out of the transceiver.

Connecting to the CM COM Port

This section describes how to install a UTP cable with RJ45 connectors and optional adapters to connect the CM COM port to a PC, VT series terminal, or modem to access local management. This section also details adapter pinout assignments.

The following parts may be needed, depending on the connection:

RJ45‐to‐DB9 female adapter (user‐supplied)

UTP cable with RJ45 connectors (user‐supplied)

RJ45‐to‐DB25 female adapter (user‐supplied)

RJ45‐to‐DB25 male adapter (user‐supplied)

Connecting the CM COM Port to an IBM PC or Compatible Device

To connect an IBM PC or compatible device, running the VT terminal emulation, to the CM COM port (Figure 3‐26), proceed as follows:

1.Connect the RJ45 connector at one end of the cable to the communications COM (Console) port on the CM.

2.Plug the RJ45 connector at the other end of the cable into a user‐supplied RJ45‐to‐DB9 adapter.

3.Connect the RJ45‐to‐DB9 adapter to the communications port on the IBM PC.

4.Turn on the PC and configure your VT emulation package with these parameters:

Parameter

Setting

 

 

 

Mode

7

Bit Control

 

 

Transmit

Transmit=19,200

 

 

Bits Parity

8 Bits, No Parity

 

 

 

Stop Bit

1

Stop Bit

 

 

 

Matrix X16-C Chassis Installation Guide 3-29

Image 61
Contents Enterasys Matrix Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Supplement to Product Instructions Vcci Notice Declaration of Conformity Enterasys Networks, Inc Firmware License Agreement Viii Page Page Contents Index Appendix a Specifications and Regulatory ComplianceFigures Tables Who Should Use This Guide Using This GuideFor information about Refer to Conventions Used in This Guide Using the Matrix X Router Manual SetGetting Help Commonly Used AcronymsGetting Help Xviii About This Guide System Description OverviewMatrix X16-C Chassis as Shipped Front View Matrix X16-C Chassis as Shipped Rear View X16-C Input/Output Modules FeaturesX16-C Control Module Installing Redundant CMs into an Active Matrix X Router CM1 Monitor Values X16-C Fabric ModulePower Supply LEDs X16-C Redundant Power SuppliesAuto-Ranging Power Supplies Power Supply ReplacementRack-Mountable Chassis Features Overview Site Guidelines Site and Configuration GuidelinesConfiguration Guidelines Required Tools Matrix X16-C Chassis SetupShipping straps Shipping box Shipping skid Unpacking the Matrix X16-C ChassisShipping bag Shipping skid Chassis Accessory packageDisassembly Steps 6 through Setup Order Setting Up the Matrix X16-C ChassisInstalling the Matrix X16-C Chassis Installing Optional Rack Support Brackets Rack Rack support brackets Bracket screws Installing Optional Mid-Mount BracketsFastening Mid-Mount Brackets To rack‐mount the Matrix X16‐C chassis, proceed as follows Rack Mounting the Matrix X16-C ChassisRack Mounting the Matrix X16-C Chassis Rack Mounting the Mid-Mounted Chassis Chassis Bonding and GroundingTelcordia GR-1089 Grounding Hole Pattern and Cable Attaching the Electrostatic Discharge Wrist Strap Installing and Removing a Power SupplyGrounding Receptacle Plug Wrist strap Installing a Power Supply Power Supply PlanningPower supply slot PS1 Power supply coverplate Vent plate 13 Removing Power Supply Vent Plate15 Removing Blank Coverplate from Power Supply Slot 14 Installing Power Supply ModuleInlet power cord AC inlet AC1 Removing a Power SupplyInstalling a Fan Tray Installing and Removing a Fan Tray17 Removing Bottom Bezel Installing and Removing IOMs Installing and Removing ModulesRemoving a Fan Tray Captive screws IOM guide rails Ejector handles IOM slot21 Removing IOM Coverplate 20 Engaging Ejector HandlesControl Module slot Guide rails Captive screws Installing and Removing CMsReplacing the CM Battery 23 Installing Fabric Module Installing and Removing FMs Installing an XFP/SFP Module XFP transceiver Port slot Release handle SFP transceiver Removing an XFP/SFP Module25 Attaching LC or MT-RJ Cable Connector Connecting Fiber-Optic CablesParameter Setting Connecting to the CM COM Port26 Connecting an IBM PC or Compatible Connecting the CM COM Port to a VT Series Terminal27 Connecting a VT Series Terminal Connecting the CM COM Port to a ModemCOM Port Adapter Wiring and Signal Diagram Adapter Wiring and Signal AssignmentsVT Series Port Adapter Wiring and Signal Diagram RJ45 DB25 Connecting to the CM USB PortModem Port Adapter Wiring and Signal Diagram RJ45 DB25 Compact Flash card Connector Control Module Installing a Compact Flash CardUSB device Control Module USB port Removing the DIMMs Installing the Memory Upgrade KitConnector fingers Connector arms Installing the DIMMsOptional Cable Management Kit To install the Cable Management Kit, proceed as follows Installing the Optional Cable Management Kit33 Installing the Bottom Cable Management Assembly 34 Securing Cables Using Velcro Cable Straps 35 Connecting 20 Amp AC Power Cord to the Power Supply Powering Up the Matrix X16-C ChassisPower Supply LEDs LEDs and Reset ButtonDC/AC Power Supply PS1-PS6 LED Definitions Function LED Activity DC Power LED37 Fan Tray LED Fan Tray LEDsControl and Fabric Module LEDs Module LEDs and Reset ButtonFan Tray LED Definitions Function LED ActivityState LED Activity Control and Fabric Module LED DefinitionsCM LEDs Only State LED Activity IOM LED Definitions IOM LEDsStatus LED LED Activity Ethernet Port LED RX/TX LED ActivityConfiguring Dhcp First-Time Quick ConfigurationAssigning an IP Address to eth0 Naming the Matrix X16-C Enabling NTPTable A-1 Matrix X-16C Specifications Chassis, Power Supply, and Fan Tray SpecificationsSpecification AC Power Supply ModuleFan Tray Table A-2 AC Power Supply RequirementsEnvironmental Table A-4 Redundancy Configurations for AC Line 100-120 Vac Table A-3 Module Power SpecificationsTable A-5 Redundancy Configurations for AC Line 200-240 Vac Table A-6 Twist Lock Power Cord Options Gigabit Ethernet Transceiver Specifications XFPTable A-8 XFP Fiber-Optic Specifications Module Wavelength Tx Power Rx Sensitivity Link PowerTable A-9 Recommended Cable Types and Specifications Gigabit Ethernet Transceiver Specifications SFPType Max. Reach Min. Reach1 Connector MGBIC-LC01/MGBIC-MT01 Specifications 1000BASE-SX SFP Input/Output SpecificationsTable A-10 Mini-GBIC Input/Output Port Specifications Table A-11 MGBIC-LC01 / MGBIC-MT01 Optical SpecificationsMGBIC-LC09 Specifications 1000BASE-LX MGBIC-LC03 Specifications 1000BASE-SXMGBIC-02 Specifications 1000BASE-T MGBIC-08 Specifications 1000BASE-ELXTable A-17 MGBIC-08 Optical Specifications Table A-19 MGBIC-02 SpecificationsCOM Port Pinout Assignments Pin Signal Name Input/OutputRegulatory Compliance Table A-20 COM Port Pin AssignmentsPage Index Mtbf RX/TX LED Index-4