Power Supply Requirements, Specifications, and Twist Lock Options
Table A-1 Matrix X-16C Specifications (continued)
Item | Specification |
|
|
Fan Tray |
|
|
|
Dimensions | 4.13 cm H x 12.7 cm W x 56.52 cm D |
| 1.625 in. H x 5.0 in. W x 22.25 in. D |
Weight | 3.31 kg (7.3 lb) |
MTBF (Predicted) | 381,219 hours |
|
|
Environmental |
|
|
|
Operating Temperature | 5°C to 40°C (41°F to 104 °F) |
Storage Temperature | |
Operating Relative Humidity | 5% to 95% |
|
|
Power Supply Requirements, Specifications, and Twist Lock Options
The requirements for Matrix X Router AC power supply modules are shown in Table A‐2:
Table A-2 AC Power Supply Requirements
Item | Specification | |
|
| |
Input Frequency | 50 to 60 Hz | |
Input (Voltage/Current) | 100 to 125 | Vac: 16 A |
| 200 to 240 | Vac: 8 A |
Output Power | 1160/1500 Watts | |
|
|
|
The power specifications for Matrix X Router modules, shown in Table A‐3, and redundancy configuration tables, shown in Table A‐4 and Table A‐5, are useful guides for power budget planning. To estimate a power budget, simply total the wattage of each installed module, making sure the combined wattage consumed is no greater than 100% of the output of the power supply(ies).
For example, if you install one CM and FM, three fan trays, and six IOMs (X‐G32‐00) at
1500 Watts/220 Vac, your total power required is 1735 watts. You would be required to install a minimum of two power supplies to support this configuration or three power supplies for N + 1 redundancy. A second example including two CMs and FMs, six fan trays, and sixteen IOMs (X‐G32‐00s) at 1160 Watts/110 Vac would yield 3040 watts, requiring a minimum of three power supplies for this configuration or four power supplies for N + 1 redundancy.