Dialogic TX4000 PCI SS7 installation manual Configuring SS7 Monitor mode

Page 18

Installing the TX 4000 board

TX 4000 PCI SS7 Network Interface Board Installation Manual

The following illustration shows the H.100 termination DIP switch:

S2

ON

12 34 567 8

OFF

Configuring SS7 Monitor mode

DIP switch S3 controls the SS7 Monitor mode. The DIP switch is located on the front of the board, to the right of the T1/E1 trunk connectors. By default, all S3 switches are set to the ON position. This setting disables SS7 Monitor mode. When SS7 Monitor mode is disabled, the TX board is an active participant in the network.

To enable SS7 Monitor mode, set the S3 switches to the OFF position. In this mode, the board becomes a passive listening device that monitors network traffic. For information on connecting the monitoring server (with an installed TX board) to the network and installing the SS7 Monitor software, refer to the Dialogic® NaturalAccess™ SS7 Monitor Developer's Reference Manual and to the Installing Dialogic® NaturalAccess™ SS7 Monitor Software instructions.

Note: The switches in DIP switch S3 must be set to either all ON or all OFF.

The following illustration shows the Monitor mode DIP switch:

S3

ON

1 2 3 4

OFF

18

Dialogic Corporation

Image 18
Contents July Copyright and legal notices Revision history Revision Release datePage Table Of Contents Hardware specifications Introduction Current terminologyPage TX 4000 board features Overview of the TXBoard TX 4000 board provides PCI bus connectivity Software components Utilities and demonstration programs Utility DescriptionProgram Demonstrates how to Page Installing the TX 4000 board System requirementsInstallation summary Step Description For details, refer toConfiguring the hardware Configuring H.100 bus terminationConfiguring SS7 Monitor mode DIP switch S1 Installing the board Step ActionConfiguring the TX 4000 board Using the configuration utilityDirectory Assigning a CP number TxcpcfgAdding a board Txcpcfg bus slot updatedCPnumber Changing a CP numberMoving a board Removing a board Saving configuration changes # Command Bus Slot CP Number TxcpcfgPage Connections Connectors and cablesEstablishing network Dialogic MD1 RJ-45 interfaceDual T1/E1 120 ohm adapter cable Ethernet interfacesConnecting to the network E1 network considerations T1 network considerationsTesting in loopback mode Connecting TX boards for redundancy TDM configurationSingle-node redundant signaling server IP network configurationDual-node redundant signaling server Verifying the installation Off Trunk has not been configuredExternal connection status LEDs Ethernet LEDs Following table describes the functionality of each LEDBoot code Leds Board status LEDsColor Status when illuminated Number Status LEDsVerifying the board installation Page Feature Specification Hardware specificationsGeneral hardware specifications PhysicalEnvironment Power requirementsCompliant interface Software environmentCept E1 G.703 telephony interface DSX-1 telephony interfacePage Index Sigtran